97¹ú¼Ê

Àë±ðÔËάÄÚÚ§ È«ÓòЭͬÌáЧ Ø­ 97¹ú¼ÊÍøÂçÔËά°ü¹ÜÂÄÀú·ÖÏí»á
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
RG-S5310-24GT4XS-P-E
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×µçÈý²ãÍø¹ÜÐͽÓÈëPoE+¹©µç½»Á÷»ú£¬4¸öÍòÕ×ÉÏÐпÚ£¬RG-S5310-24GT4XS-P-E

ÓÃÓÚ´óÐÍÍøÂçȫǧÕ×½ÓÈ룬֧³ÖPoE+¹©µç

²úÆ·ÌØÕ÷£º

  • ¶Ë¿ÚÀàÐ͸»ºñ£¬24¸öÒÔÌ«Íø¿Ú£¬4¸öÍòÕ×¹â¿ÚÓÃÓÚÉÏÁª
  • ×ñÕÕIEEE 802.3afºÍIEEE 802.3at±ê×¼£¬Ö§³ÖPoE+¹©µç
  • Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ£¬ÎÞа×éÍøÐÔÄÜÇ¿
  • ¶àÖÖÍøÂçÇå¾²Õ½ÂÔ£¬ÊµÊ±¼à²â£¬°ü¹ÜÍøÂçÎȹÌÔËÐÐ
  • ¶àÖØÍøÂç¹ÜÀí·½·¨£¬ ʵÏÖ¼òÆÓÇáËɵÄÍøÂçά»¤
Á¬Ã¦×Éѯ
Èí¼þЭÒé
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¸ß¿É¿¿ÐÔ
VRRP
STP/RSTP/MSTP
RLDP
ERPS
BFD
VSU£¨ÐéÄ⻯ÊÖÒÕ£©
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Èý²ã·ÓÉЭÒé
Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ
Ö§³ÖRIP
RIPng
OSPFv2
OSPFv3
BGP4
BGP4+
IS-IS
Routing Policy
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Ó¦ÓÃЭÒé
DNS
DHCP Relay
DHCP Server
DHCP Client
Telnet
TFTP
FTP
NTP
SNTP
Netconf
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¹ÜÀíÌØÕ÷
SNMP
Web
CLI(Telnet/Console)
RMON(1,2,4,9)
Syslog/Debug
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Çå¾²ÌØÕ÷
CPP
NFPP
DHCP snooping
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞËÙ
Ö§³Ö·ÀÍø¹ØARPÓÕÆ­
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤
×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³Ö¶Ë¿Ú±£»¤

ÍòÕ×ÉÏÁªÈý²ã½ÓÈë½»Á÷»ú RG-S5310-24GT4XS-P-E

¿ÉÓÃÓÚ´óÐÍÆóÊÂÒµÔ°ÇøÄÚ¾ÖÓòÍøµÄȫǧÕ×½ÓÈ룬4¸öÍòÕ×¹â¿ÚÓÃÓÚÉÏÁª¸ßËÙ´«ÊäÊý¾Ý
24¸öPoE+ǧÕ××Ô˳ӦÒÔÌ«Íø¿Ú£¬Îª½ü¾àÀëÓªÒµÌṩ¸ßËÙÓÃÍøÌåÑé

PoE+¹©µç,Öª×ã²î±ðÖÕ¶Ë×°±¸¹©µçÐèÇó

¿ÉÒÔ×Ô¶¯¼ì²â²¢¶Ô PoE ×°±¸ÌṩËùÐèµÄ¹¦ÂÊ£¬ÎªÇÐºÏ IEEE 802.3af µÄ×°±¸Ìṩ×î´ó 15.4W µÄ¹¦ÂÊ£¬ÇÐºÏ IEEE
802.3at µÄ×°±¸Ìṩ¸ß´ï 30W µÄ¹¦ÂÊ,Öª×ã°²·À¼à¿Ø¡¢µç»°¾Û»áϵͳ¡¢ÎÞÏßÁýÕֵȳ£¼û PoE ¹©µçµÄÐèÇó

Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ£¬ÎÞа×éÍøÐÔÄÜÇ¿

ºÁÃë¼¶¹ÊÕϻָ´
¸ßÀ©Õ¹
¼ò»¯×éÍø
VSUÐéÄâϵͳºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬ÈçÓö¹ÊÕÏ£¬¿ÉºÁÃë¼¶Çл»Á´Â·£¬°ü¹ÜÍøÂç²»ÖÐÖ¹

¶àÖÖÍøÂçÇå¾²Õ½ÂÔ£¬ÊµÊ±¼à²â£¬°ü¹ÜÍøÂçÒ»Á¬½áʵÐÔ

ÌṩCPU±£»¤Õ½ÂÔ£¬¿ØÖÆ·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿¾Þϸ£¬±£»¤CPUʹÓÃÂÊ
Ìṩ»ù´¡ÍøÂç±£»¤Õ½ÂÔ£¨NFPP£©£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§¾ÙÐиôÀ룬°ü¹ÜÍøÂçÇå¾²ÎȹÌ

¶àÖØÍøÂç¹ÜÀí·½·¨ ʵÏÖ¼òÆÓÇáËɵÄÍøÂçά»¤

¹ÜÀíÌØÕ÷
¹ÜÀí·½·¨
¶ą̀װ±¸¹ÜÀí
Ö§³ÖRMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾ÌØÕ÷£¬°ü¹ÜÒ»Ñùƽ³£ÓÃÍøµÄÕý³£Õï¶ÏÓëά»¤

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ÐͺŠRG-S5310-24GT4XS-E
RG-S5310-24GT4XS-P-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-P-E
RG-S5310-24SFP4XS-E RG-S5310-48SFP4XS-E
½Ó¿Ú¹æ¸ñ
¹Ì»¯ÓªÒµ½Ó¿Ú 24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 48¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 24¸öǧÕ×SFP¹â¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 48¸öǧÕ×SFP¹â¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú
ϵͳ¹æ¸ñ
½»Á÷ÈÝÁ¿ 1.36Tbps/13.6Tbps
°üת·¢ÂÊ 291Mpps/770Mpps 560Mpps/770Mpps 291Mpps/770Mpps 560Mpps/770Mpps
³ß´çÓëÖØÁ¿
²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© 442.0mm x 420.0mm x 43.6mm
µçÔ´Ó빦ºÄ
¶î¶¨ÊäÈëµçѹ RG-S5310-24GT4XS-E¡¢RG-S5310-48GT4XS-E¡¢RG-S5310-24SFP4XS-E¡¢RG-S5310-48SFP4XS-E½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ¹æÄ£100V~240V£¬ÆµÂÊ50/60Hz£»

RG-S5310-24GT4XS-P-E¡¢RG-S5310-48GT4XS-P-EµçÔ´£¬½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ¹æÄ£200V~240V£¬ÆµÂÊ50/60Hz
×î´óÊäÈëµçѹ RG-S5310-24GT4XS-E¡¢RG-S5310-48GT4XS-E¡¢RG-S5310-24SFP4XS-E¡¢RG-S5310-48SFP4XS-E½»Á÷£¨AC£©ÊäÈ룺
  • ×î´óµçѹ¹æÄ£90V~264V£¬ÆµÂÊ50/60Hz£»

RG-S5310-24GT4XS-P-E¡¢RG-S5310-48GT4XS-P-EµçÔ´£¬½»Á÷£¨AC£©ÊäÈ룺
  • ×î´óµçѹ¹æÄ£176V~264V£¬ÆµÂÊ50/60Hz
Õû»ú¹¦ºÄ ·ÇPOE£º¡Ü40W
POE£º<810W£¨PoEÂúÔØ£©£¬<85W£¨²»´øPoE¸ºÔØ£©
·ÇPOE£º¡Ü55W
POE£º<1570W
£¨PoEÂúÔØ£©£¬<75W£¨²»´øPoE¸ºÔØ£©
¡Ü85W ¡Ü108W
ÇéÐÎÓë¿É¿¿ÐÔ
ÊÂÇéÎÂ¶È 0¡æ~45¡æ
´æ´¢ÎÂ¶È -40¡æ~70¡æ
ÊÂÇéʪ¶È 10%~90%RH
´æ´¢Êª¶È 5%~95%RH
ͨѶ½Ó¿Ú·ÀÀ× 10KV£¨ÓªÒµ½Ó¿Ú£©
µçÉÈ 1¸ö¹Ì»¯µçÉÈ V3.XXÒÔϰ汾£º1¸ö¹Ì»¯µçÉÈ
V3.XX¼°ÒÔÉϰ汾£º2¸ö¹Ì»¯µçÉÈ
2¸ö¹Ì»¯µçÉÈ 2¸ö¹Ì»¯µçÉÈ
µçÉÈ¼à¿Ø Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§

Èí¼þ¹æ¸ñ

ÐͺŠRG-S5310-24GT4XS-E
RG-S5310-24GT4XS-P-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-P-E
RG-S5310-24SFP4XS-E RG-S5310-48SFP4XS-E
L2ÌØÕ÷ Ö§³Ö¶þ²ãÁ´Â·¾ÛºÏ
Ö§³ÖSTP¡¢RSTP¡¢MSTP£¬MSTPʵÀýÊýÄ¿65¸ö£¬·ºÆðÁ´Â·¹ÊÕϺ󣬸÷¸ö×°±¸Äܹ»¾ÙÐÐÌìÉúÊ÷µÄÖØÐÂÅÌËã
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
ACL Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢SP+WRR¡¢RED/WREDÐÐÁе÷Àí
Mirror Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖSPANÍâµØ¾µÏñºÍRSPAN¡¢ERSPANÔ¶³Ì¾µÏñ
Ö§³Ö»ùÓÚÁ÷µÄÍâµØ¡¢Ô¶³Ì¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
Çå¾²ÌØÕ÷ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞËÙ
Ö§³Ö·ÀÍø¹ØARPÓÕÆ­
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖIP SOURCE Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
»·ÍøÐ­Òé Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·¼æÈÝ
PoE ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3afºÍ802.3atµÄ¹©µç±ê×¼
Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö»ùÓÚʱ¼äÕ½ÂÔ¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
×¢£º½öRG-S5310-24GT4XS-P-EºÍRG-S5310-48GT4XS-P-EÖ§³ÖPoEÏà¹Ø¹¦Ð§
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2?¡¢OSPFv3¡¢BGP¡¢BGP4+¡¢ISIS¡¢ISISv6£¬¶¯Ì¬Â·ÓÉÖÐÖ§³Ö·ÓÉÖØ·Ö·¢£¬Ö§³ÖÕë¶Ô¶¯Ì¬Â·ÓÉЭÒéµÄMD5ÈÏÖ¤
Routing Policy
ECMP
IPv6»ù´¡Ð­Òé IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 Tracert¡¢IPv6×é²¥µÈ
×é²¥ Ö§³ÖIGMP v1£¬v2£¬v3
Ö§³ÖIGMP v1£¬v2ºÍv3 Snooping
Ö§³ÖPIM-DM£¬PIM-SM£¬PIM-SSM
SAVI Ö§³Ö·ÀNS/NA/RS/RA±¨ÎÄÓÕÆ­¹¦Ð§
Ö§³Ö·À˽ÉèIPv6µØÖ·
Ö§³Ö»º´æ²»·¨ÖÕ¶ËÐÅÏ¢
MPLS Ö§³ÖMPLS VPN
Ö§³ÖMPLS IPv6
VSUÌØÕ÷ Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó
Ö§³Öͨ¹ý±ê×¼ÓªÒµ¿ÚʵÏÖÐéÄ⻯
VxLAN (ÊÚȨ֧³Ö)Ö§³ÖBGP EVPN¡¢ÂþÑÜʽAnycastÍø¹Ø
¿É¿¿ÐÔ µçÔ´Ö§³Ö1+1ÈßÓ౸·Ý
Ö§³ÖBFD
Ö§³Ö»ùÓÚipv6µÄÍø¹ØÈȱ¸Ð­Òé(VRRPv3)
ÁãÉèÖà ֧³ÖCWMP(TR069)ЭÒé±ê׼ЭÒé
¹ÜÀíÌØÕ÷ SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢Web¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢sFLOW¡¢¹«ÓÐÔÆÆ½Ì¨¹ÜÀí
Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

40/100G¹âÏËÏß
ÍòÕ×¹âÏËÏß
ǧÕ×Ë«½ÊÏß
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
µçÔ´(2)
ÃüÃû¹æÔò(2)
»·Â·¼ì²â(2)
³ß´ç(1)
97¹ú¼Ê 2022Äê07ÔÂ25ÈÕ
RG-S5310-24GT4XS-EÖÐ-E´ú±íʲôÒâ˼ £¿
ÓÐÓÃ 52 ÎÞÓÃ 10

ÐͺÅÃûÖÐEÌåÏÖÔÚͬϵÁн»Á÷»úÖÐÐÔÄÜÔöÇ¿°æµÄÒâ˼¡£

97¹ú¼Ê 2022Äê07ÔÂ25ÈÕ
½»Á÷»úµÄ»·Â·¼ì²âÔõôʵÏÖµÄÄØ £¿
ÓÐÓÃ 518 ÎÞÓÃ 70

ͨ¹ý97¹ú¼Ê×ÔÖ÷Ñз¢µÄÓÃÓÚ¿ìËÙ¼ì²âÒÔÌ«ÍøÁ´Â·¹ÊÕϵÄÁ´Â·Ð­Òé——RLDP À´ÊµÏֵġ£
Ò»Ñùƽ³£µÄÒÔÌ«ÍøÁ´Â·¼ì²â»úÖÆ¶¼Ö»ÊÇʹÓÃÎïÀíÅþÁ¬µÄ״̬£¬Í¨¹ýÎïÀí²ãµÄ×Ô¶¯Ð­ÉÌÀ´¼ì²âÁ´Â·µÄÁ¬Í¨ÐÔ¡£
¿ÉÊÇÕâÖÖ¼ì²â»úÖÆ±£´æÒ»¶¨µÄ¾ÖÏÞÐÔ£¬ÔÚһЩÇéÐÎÏÂÎÞ·¨ÎªÓû§Ìṩ¿É¿¿µÄÁ´Â·¼ì²âÐÅÏ¢£¬ºÃ±ÈÔÚ¹âÏË¿ÚÉϹâÏËÎüÊÕÏß¶Ô½Ó´í£¬ÓÉÓÚ¹âÏËת»»Æ÷µÄ±£´æ£¬Ôì³É×°±¸¶ÔÓ¦¶Ë¿ÚÎïÀíÉÏÊÇlinkup µÄ£¬µ«ÏÖʵ¶ÔÓ¦µÄ¶þ²ãÁ´Â·È´ÊÇÎÞ·¨Í¨Ñ¶µÄ¡£ÔٺñÈÁ½Ì¨ÒÔÌ«Íø×°±¸Ö®¼ä¼ÜÉè×ÅÒ»ÆäÖÐÐÄÍøÂ磬ÓÉÓÚÍøÂç´«ÊäÖмÌ×°±¸µÄ±£´æ£¬ÈôÊÇÕâЩÖмÌ×°±¸·ºÆð¹ÊÕÏ£¬½«Ôì³ÉͬÑùµÄÎÊÌâ¡£
ʹÓÃRLDP ЭÒéÓû§½«¿ÉÒÔÀû±ã¿ìËٵؼì²â³öÒÔÌ«Íø×°±¸µÄÁ´Â·¹ÊÕÏ£¬°üÀ¨µ¥ÏòÁ´Â·¹ÊÕÏ¡¢Ë«ÏòÁ´Â·¹ÊÕÏ¡¢»·Â·Á´Â·¹ÊÕÏ¡£

Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ £¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖà £¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù £¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£© £¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£© £¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼