ÖÐÎÄ
Ö§³Ö¹âµç»ìÏýÀÂÈëÊÒ£¬Öª×ãÔ°ÇøÍøÂçµÄ¼à¿Ø¡¢ÎÞÏߵȳ¡¾°ÐèÇó
ÀàÐÍ£º
²úÆ·ÌØÕ÷£º
|
Ó²¼þ¹æ¸ñ |
RG-PF2920-8GT2MG2XS |
RG-PF2920-16GT2XS |
|
¹Ì»¯ÓªÒµ½Ó¿Ú |
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G×Ô˳Ӧµç¿Ú 2¸ö1G/10G SFP+¹â¿Ú |
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö10G SFP/SFP+¹â¿Ú |
|
¹Ì»¯¹ÜÀí½Ó¿Ú |
1¸öConsole½Ó¿Ú |
|
|
½»Á÷ÈÝÁ¿ |
432Gbps/4.32Tbps |
|
|
°üת·¢ÂÊ |
84Mpps/126Mpps |
92Mpps/126Mpps |
|
SFP+¹â½Ó¿Ú |
Ö§³Ö10GBase-RºÍ1000Base-X |
|
|
µçÔ´ |
ͨ¹ýʱ¹âÖ÷»úÒýÈë¹âµç»ìÏýÀ¹©µç Á½Â·PoEÊäÈ루802.3AT£©£ºPoE-IN1¡¢PoE-IN2 ¶î¶¨µçѹ¹æÄ££º44V~ 57V ¶î¶¨µçÁ÷£º0.5A |
|
|
ÊäÈë¶ÔµØÐ¹µçÁ÷²ÎÊý |
≤3.5mA |
|
|
EEE½ÚÄÜ |
Ö§³Ö |
|
|
PoEÊä³ö¹¦Ð§ |
²»Ö§³Ö |
|
|
Õû»ú¹¦ÂÊ |
Õû»ú¹¦ºÄ£¼20W |
|
|
ÊÂÇéÎÂ¶È |
ÊÒÄÚ¹Òǽ&»ú¼Ü&ÇżܵȿªÍس¡¾°£º0ºC µ½55ºC£¨0-1800mº£°Î£© ˵Ã÷£ºº£°Î1800~5000m£ºº£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ |
|
|
´æ´¢ÎÂ¶È |
-40ºCµ½ 70ºC |
|
|
ÊÂÇéʪ¶È |
10% µ½ 90% RH |
|
|
´æ´¢Êª¶È |
5% µ½ 95% RH |
|
|
µçÉÈ |
ÎÞµçÉÈ×ÔȻɢÈÈ |
|
|
ÖÇÄÜ¿ØÎ |
Ö§³Öζȸ澯¼°¸ßα£»¤¹¦Ð§ |
|
|
EMC |
GB/T 9254.1-2021 |
|
|
°²¹æ |
GB 4943.1-2022 |
|
|
²úÆ·³ß´ç£¨¿íxÉîx¸ß£© |
224.0mm x 307.4mm x 78.8mm |
|
|
ÖØÁ¿£¨µ¥Î»£ºkg£© |
2.75kg£¨º¬°ü×°£© |
|
|
Ó²¼þ¹æ¸ñ |
RG-PF2920U-4GT1MS-P |
RG-PF2920-DPBOX-P |
|
¹Ì»¯ÓªÒµ½Ó¿Ú |
4¸ö10/100/1000M×Ô˳Ӧµç¿Ú |
1¸ö10/100/1000M×Ô˳Ӧµç¿Ú |
|
¹Ì»¯¹ÜÀí½Ó¿Ú |
1¸öConsole½Ó¿Ú |
/ |
|
½»Á÷ÈÝÁ¿ |
432Gbps/4.32Tbps |
NA |
|
°üת·¢ÂÊ |
78Mpps/126Mpps |
NA |
|
SFP+¹â½Ó¿Ú |
Ö§³Ö2500Base-XºÍ1000Base-X |
Ö§³Ö1000Base-X |
|
µçÔ´ |
ͨ¹ýʱ¹âÖ÷»úÒýÈë¹âµç»ìÏýÀ¹©µç |
ͨ¹ýʱ¹âÖ÷»úÒýÈë¹âµç»ìÏýÀ¹©µç |
|
ÊäÈë¶ÔµØÐ¹µçÁ÷²ÎÊý |
≤3.5mA |
NA |
|
EEE¹¦Ð§ |
Ö§³Ö |
²»Ö§³Ö |
|
PoE½Ó¿Ú |
1~4ÒÔÌ«Íøµç½Ó¿ÚÖ§³ÖPoE¹¦Ð§ |
1¿ÚΪÏÂÐÐPOE/POE+½Ó¿Ú |
|
PoEÊä³ö¹¦ÂÊ |
ÿ½Ó¿Ú×î´ó¹©µç30W |
ÿ½Ó¿Ú×î´ó¹©µç30W |
|
Õû»ú¹¦ºÄ |
Õû»ú¹¦ºÄ£¨²»´øPoE¸ºÔØ£©≤15W |
Õû»ú¹¦ºÄ(²»´øPoE¸ºÔØ)≤3W |
|
ÊÂÇéÎÂ¶È |
»ú¼ÜµÈ¿ª·Å³¡¾°£º0ºC µ½45ºC£¨0~1800mº£°Î£© |
|
|
´æ´¢ÎÂ¶È |
-40ºCµ½ 70ºC |
-40ºCµ½70ºC |
|
ÊÂÇéʪ¶È |
10% µ½ 90% RH |
10% µ½ 90% RH |
|
´æ´¢Êª¶È |
5% µ½ 95% RH |
5% µ½ 95% RH |
|
µçÉÈ |
ÎÞµçÉÈ×ÔȻɢÈÈ |
ÎÞµçÉÈ×ÔȻɢÈÈ |
|
ÖÇÄÜ¿ØÎ |
Ö§³Öζȸ澯¼°¸ßα£»¤¹¦Ð§ |
²»Ö§³Ö |
|
EMC |
GB/T 9254.1-2021 |
GB/T 9254.1-2021 |
|
°²¹æ |
GB 4943.1-2011 |
GB 4943.1-2011 |
|
²úÆ·³ß´ç£¨¿íxÉîx¸ß£© |
200mm x 170mm x 55mm |
40.0mm x 120.0mm x 28.7mm |
|
ÖØÁ¿£¨µ¥Î»£ºkg£© |
1.5 kg£¨º¬°ü×°£© |
0.2 kg£¨º¬°ü×°£© |
|
Èí¼þ¹æ¸ñ |
RG-PF2920-8GT2MG2XS |
RG-PF2920-16GT2XS |
|
MACµØÖ·±í |
Ö§³Ö¾²Ì¬MACµØÖ· Ö§³ÖMACµØÖ·¹ýÂË |
|
|
802.1Q VLAN |
Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖPrivate VLAN Ö§³ÖProtocal based VLAN Ö§³ÖGVRP VLAN Ö§³ÖVoice VLAN |
|
|
QinQ |
Ö§³Ö»ù±¾QinQ Ö§³ÖÎÞаQinQ |
|
|
¶Ë¿Ú¾ÛºÏ |
Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨ Ö§³ÖLACP¶¯Ì¬¾ÛºÏ Ö§³ÖLACPÓÅÏȼ¶/ÐÉÌ·½·¨/×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖà ֧³ÖVSU AP |
|
|
Mirror |
Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»µÄ¾µÏñ Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¾µÏñ Ö§³ÖRSPAN¡¢ERSPAN |
|
|
DHCP |
Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Relay Ö§³ÖDHCP Snooping |
|
|
IP·ÓÉ |
Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ¡¢RIP¡¢OSPF¡¢Ripng |
|
|
ACL |
Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© Ö§ÌØMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£© Ö§³ÖACL 80 Ö§³ÖIPv6 ACL Ö§³ÖÈ«¾ÖACL Ö§³ÖACLÖØ¶¨Ïò |
|
|
QoS |
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCPÁ÷Á¿·ÖÀà Ö§³ÖSP¡¢WRR¡¢DRR¡¢WFQ¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRRÐÐÁе÷Àí |
|
|
Çå¾²ÌØÕ÷ |
¹ýÂ˲»·¨µÄMACµØÖ· Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRadiusºÍTACACS+ Ö§³ÖSSHºÍSSH V2.0 Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
|
|
EEE |
Ö§³ÖIEEE802.3az±ê×¼µÄEEE¶Ë¿ÚÐÝÃß½ÚÄÜÊÖÒÕ |
|
|
¹ÜÀíÌØÕ÷ |
Ö§³ÖSNMP¡¢Telnet¡¢Web¡¢RMON¡¢FTP¡¢TFTP¡¢NTP/SNTP¡¢RLDP¡¢Syslog/Debug |
|
|
Èí¼þ¹æ¸ñ |
RG-PF2920U-4GT1MS-P |
RG-PF2920-DPBOX-P |
|
802.1Q VLAN |
Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN |
²»Ö§³Ö |
|
Çå¾²ÌØÕ÷ |
¹ýÂ˲»·¨µÄMACµØÖ· Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ Ö§³Ö¿ÚÁî±£»¤ Ö§³ÖCPP Ö§³Ö¶Ë¿Ú±£»¤ |
²»Ö§³Ö |
|
EEE |
Ö§³ÖAPD¶Ë¿ÚÐÝÃß |
²»Ö§³Ö |
|
¹ÜÀíÌØÕ÷ |
Ö§³ÖÈ¥CLI¿ÉÊÓ»¯WEB¹ÜÀí Ö§³ÖÎïÁªÍøÐÒéMQTT Ö§³ÖSyslog/Debug¡¢SNTP |
²»Ö§³Ö |
ʹÓùâµç»ìÏýÀÂÊǺÜÊÇÇå¾²µÄ£¬»ìÏýÀ´«Êäµçѹ¼á³ÖÔÚDC48V×óÓÒ£¬ÇкÏIEEE 802.3 af/at/bt±ê×¼£¬ÎÂÉý¿É¿Ø£¬¾ß±¸×èȼƷ¼¶£¬²»»áÆð»ð£¬ÇҾ߱¸ÎÂ¶È¼à¿Ø¹¦Ð§ºÍ¹ýÁ÷±£»¤»úÖÆ£¬µ±Î¶ÈÇéÐβ»Õý³£Ê±£¬Ö±½Ó×èÖ¹¹©µçÇÒ±¨¾¯£¬±ÜÃâÏß·¶Ì·Æð»ð¡£
ÍøÏß´«ÊäÊÜÊý¾Ý´«Êä100MµÄÏÞÖÆ£¬PoF½ÏPoE½ö´«ÊäµçÔ´£¬ÎÞÊý¾Ý×ÌÈÅ£¬Í¬Ê±»ìÏýÀÂÌṩµÄ½ØÃæ»ý¸ü´ó£¬µÈЧ´«Êä×迹¸üµÍ£¬Òò´Ë´«Êä¾àÀë»á¸üÔ¶¡£