ÖÐÎÄ
½ô´ÕÐ͵ĻúÉíÉè¼ÆºÍ¸»ºñµÄÓªÒµ°å¿¨ÀàÐÍ£¬´îÔØÄ£¿é»¯²Ù×÷ϵͳ£¬Ö§³Ö¸»ºñµÄÊý¾ÝÖÐÐÄÌØÕ÷£¬Öª×ãÊý¾ÝÖÐÐij¡¾°°²ÅÅÒªÇó;´îÅä¸ßÃܶȲʹâ°å¿¨¼°³¬¾ÛºÏ²Ê¹âÄ£¿é£¬Ó¦ÓÃÓÚ¼«¼òÒÔÌ«²Ê¹âÍøÂç½â¾ö¼Æ»®4.0¡£
ÀàÐÍ£º
²úÆ·ÌØÕ÷£º
| Ó²¼þ¹æ¸ñ | RG-S7805C £¨´îÅäCM-XϵÁÐÖ÷¿Ø£© |
RG-S7808C £¨´îÅäCM-XϵÁÐÖ÷¿Ø£© |
RG-S7810C-X |
| ϵͳ¹æ¸ñ | |||
| ½»Á÷ÈÝÁ¿ | 68.2Tbps/307.2 Tbps | 106.4Tbps/460.8Tbps | 645Tbps |
| °üת·¢ÂÊ | 51200Mpps | 78600Mpps | 230400Mpps |
| ½Ó¿Ú¹æ¸ñ | |||
| Ä£¿é²å²Û | 3¸öӪҵģ¿é²å²Û 2¸ö¹ÜÀíÒýÇæ²å²Û ÄÚÖý»Á÷Íø°å |
6¸öӪҵģ¿é²å²Û 2¸ö¹ÜÀíÒýÇæ²å²Û 2¸ö½»Á÷Íø°å£¨¹ÜÀíÒýÇæ¼¯³É£© |
8¸öӪҵģ¿é²å²Û 2¸ö¹ÜÀíÒýÇæ²å²Û 4¸ö½»Á÷Íø°å²Ûλ |
| ³ß´çÓëÖØÁ¿ | |||
| ²úÆ·³ß´ç£¨¿íxÉîx¸ß£© | 442mm x 451mm x 175mm (²»º¬×ßÏß¼Ü) | 442.0mm x 465.0mm x 441.7mm (²»º¬×ßÏß¼Ü) | 442.5mm x 560.0mm x 442.0mm (²»º¬×ßÏß¼Ü) 442.5mm x 662.0mm x 442.0mm (º¬×ßÏß¼ÜÓë°ÑÊÖ) |
| »ú¼Ü³ß´ç | 4U | 10U | 10U |
| É¢ÈÈϵͳ | |||
| É¢ÈÈ | ǰºó·çµÀÉ¢ÈÈÉè¼Æ£¬ÓҲ࿪¿×ÌṩӪҵ¿¨É¢ÈÈ | ǰºó·çµÀÉ¢ÈÈÉè¼Æ£¬ÓҲ࿪¿×ÌṩӪҵ¿¨É¢ÈÈ | YÐÍ·çµÀÉè¼Æ |
| µçÔ´Ó빦ºÄ | |||
| ¿ª¹ØµçÔ´ | 5(º¬ÍâÖÃPoEµçÔ´) | 10(º¬ÍâÖÃPoEµçÔ´) | 12(º¬ÍâÖÃPoEµçÔ´) |
| µçÔ´×î´óÊä³ö¹¦ÂÊ | RG-PA300I-F£º 90~264V£¬¹¦ÂÊ£º300W£» RG-PA460I-F£º 90~264V£¬¹¦ÂÊ£º460W£» RG-PA1000I-F£º 90~176V£¬¹¦ÂÊ£º800W£» 176~264V£¬¹¦ÂÊ£º1000W£» RG-PA1600I-PL£º 90~176V£¬¹¦ÂÊ£º1000W 176~264V£¬¹¦ÂÊ£º1600W |
RG-PA600I-F£º 90~264V£¬¹¦ÂÊ£º600W RG-PA1600I-F£º 90~176V£¬¹¦ÂÊ£º1200W 176~264V£¬¹¦ÂÊ£º1600W RG-PD600I-F£º -40V~-75V£¬¹¦ÂÊ£º600W RG-PA1600I-PL£º 90~176V£¬¹¦ÂÊ£º1000W 176~264V£¬¹¦ÂÊ£º1600W |
RG-PA1600I£º 90~176V£¬¹¦ÂÊ£º1200W 176~264V£¬¹¦ÂÊ£º1600W RG-PA600I£º 90~264V£¬¹¦ÂÊ£º600W£» RG-PD600I£º -40~-75V£¬¹¦ÂÊ£º600W RG-PA1600I-PL£º 90~176V£¬¹¦ÂÊ£º1000W 176~264V£¬¹¦ÂÊ£º1600W |
| ÇéÐÎÓë¿É¿¿ÐÔ | |||
| ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£© | > 200,000Сʱ | ||
| ÊÂÇéÎÂ¶È | 0¡æ~50¡æ | ||
| ´æ´¢ÎÂ¶È | -40¡æ~70¡æ | ||
| ÊÂÇéʪ¶È | 10%~90%RH£¨ÎÞÀäÄý£© | ||
| ´æ´¢Êª¶È | 5%~95%RH | ||
| ÊÂÇ麣°Î | -500~5000M | ||
| Èí¼þ¹æ¸ñ | RG-S7805C £¨´îÅäCM-XϵÁÐÖ÷¿Ø£© |
RG-S7808C £¨´îÅäCM-XϵÁÐÖ÷¿Ø£© |
RG-S7810C-X |
| ×°±¸ÐéÄ⻯ | Ö§³ÖVSU(Virtual Switching Unit,ÐéÄâ½»Á÷µ¥Î») | ||
| SDN | Ö§³ÖOpenFlow 1.3 Ö§³ÖNetconf |
||
| L2ÌØÕ÷ | Ö§³ÖIEEE 802.3£¨10Base-T£©¡¢802.3u£¨100Base-T£©¡¢IEEE 802.3z£¨1000BASE-X£©¡¢802.3ab£¨1000Base-T£©¡¢IEEE 802.3ae£¨10Gbase£©¡¢IEEE 802.3ba£¨40G/100Gbase£© Ö§³Ö¶þ²ãÁ´Â·¾ÛºÏ Ö§³ÖJumbo Frame Ö§³ÖSTP¡¢RSTP¡¢MSTP Ö§³Ö»ùÓڶ˿ڵġ¢Ô´ IPµØÖ·µÄ¡¢Ô´MACµØÖ·µÄ¡¢ÐÒéµÄ802.1Q VLAN£¬VLAN IDÊýÄ¿4095 ¸ö Ö§³ÖSuper VLAN Ö§³ÖGVRP Ö§³ÖQinQ¡¢ÎÞаQinQ Ö§³ÖLLDP Ö§³ÖERPS£¨G.8032£© |
||
| MPLS | Ö§³ÖMPLS L3VPN Ö§³ÖMPLS 6VPE Ö§³ÖMPLS IPv6 |
||
| IPv4ÌØÕ÷ | Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPv1¡¢RIPv2¡¢OSPFv2¡¢IS-ISv4¡¢BGP4 Ö§³ÖVRRP Ö§³ÖµÈ¼Û·ÓÉ Ö§³ÖÕ½ÂÔ·ÓÉ Ö§³ÖGREËíµÀ |
||
| IPv6ÌØÕ÷ | Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+¡¢IS-ISv6¡¢MLDv1/v2 Ö§³ÖVRRPv3 Ö§³ÖµÈ¼Û·ÓÉ Ö§³ÖÕ½ÂÔ·ÓÉ Ö§³ÖÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀ¡¢Ö§³ÖGREËíµÀµÈ |
||
| ×é²¥ | Ö§³ÖIGMP v1,v2,v3 Ö§³ÖIGMP Snooping Ö§³ÖIGMP Proxy Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓÉÐÒé Ö§³ÖMLD Ö§³Ö×é²¥¾²Ì¬Â·ÓÉ |
||
| VXLAN | Ö§³ÖVXLAN¶þ²ãÍøÇÅ Ö§³ÖVXLANÈý²ãÍø¹Ø Ö§³ÖEVPN VXLAN |
||
| ACL | Ö§³ÖIP±ê×¼ACL¡¢IPÀ©Õ¹ACL¡¢MACÀ©Õ¹ACL Ö§³Ö¶þ²ãºÍÈý²ã¶Ë¿ÚACL Ö§³ÖVLAN ACL Ö§³Öר¼Ò¼¶ACL Ö§³ÖACL 80 Ö§³ÖIPv6 ACL Ö§³ÖÈëÆ«ÏòºÍ³öÆ«ÏòµÄACL±¨ÎĹýÂË |
||
| QoS | Ö§³Ö802.1P Ö§³ÖSP¡¢WRR¡¢SP+WRRµÈÐÐÁе÷Àí»úÖÆ Ö§³ÖRED/WRED Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ Ö§³ÖDiffserv ÿ¸ö¶Ë¿ÚµÄÓ²¼þÐÐÁÐÊýÄ¿´óÓÚ¼´ÊÇ8¸ö£¬ ¿ÉÖÁÉÙÌṩ 1 ¸öÑÏ¿áµÄ(Strict)ºÍ 1¸ö WFQ ÐÐÁÐÒÔ°ü¹ÜÍøÂç QoS µÄʵÑé |
||
| ¾µÏñ | Ö§³Ö¶à¶ÔÒ»¾µÏñ¡¢Ò»¶Ô¶à¾µÏñ¡¢»ùÓÚÁ÷µÄ¾µÏñ Ö§³ÖSPANÍâµØ¾µÏñºÍRSPAN¡¢ERSPANÔ¶³Ì¾µÏñ£¬Ö§³ÖVLANµÄ¾µÏñ |
||
| ¿É¿¿ÐÔ | Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý ¸÷×é¼þÖ§³ÖÈȲå°Î |
Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý µçÔ´Ö§³ÖN+MÈßÓ౸·Ý µçÉÈ¿òÖ§³Ö1+1ÈßÓ౸·Ý ¸÷×é¼þÖ§³ÖÈȲå°Î |
|
| Ö§³ÖÈȲ¹¶¡¹¦Ð§£¬¿ÉÔÚÏß¾ÙÐв¹¶¡Éý¼¶ Ö§³ÖGR for OSPF/IS-IS/BGP Ö§³ÖBFD for ISISv4/ISISv6/OSPFv2/OSPFv3/BGP4/BGP4+/VRRP/VRRP+/Õ½ÂÔ·ÓÉ Ö§³Ö¹â¿Ú¹ÊÕϸôÀë Ö§³ÖÆô»úϵͳ˫ÎïÀíоƬ |
|||
| Çå¾²ÐÔ | Ö§³ÖNFPP£¨»ù´¡Çå¾²±£»¤Õ½ÂÔ£© Ö§³ÖCPP£¨CPU±£»¤£© Ö§³ÖDAI£¬¶Ë¿ÚÇå¾²£¬IP Source Guard Ö§³ÖDOT1XÈÏÖ¤¡¢MACµØÖ·ÈÏÖ¤ Ö§³ÖPortalÈÏÖ¤¡¢Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤ Ö§³ÖuRPF Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁîÇå¾² Ö§³ÖÖ§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÖÆ Ö§³ÖSSHv2£¬ÎªÓû§µÇ¼ÌṩÇå¾²¼ÓÃÜͨµÀ Ö§³ÖIPv6 SAVI |
||
| ¹ÜÀíÐÔ | Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ÏÂÁîÐÐÉèÖà ֧³ÖFTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØ¹ÜÀí Ö§³ÖSNMP V1/V2c/V3 Ö§³ÖRMON Ö§³ÖNTPʱÖÓ Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´ Ö§³ÖϵͳÊÂÇéÈÕÖ¾ Ö§³ÖsFLOW Ö§³ÖTelemetry£¨GRPC£© |
||