RG-S6501-32CQ
RG-S6501-32CQ
RG-S6501-32CQ
RG-S6501-32CQ
RG-S6501-32CQ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

32¿Ú100GÊý¾ÝÖÐÐĺÐʽ½ÓÈë½»Á÷»ú £¬Ö§³ÖÏòϼæÈÝ40G £¬RG-S6501-32CQ

¸ßÃܶÈ100G½»Á÷»ú £¬Ö§³ÖRDMA £¬¹¹½¨µÍÑÓʱÊý¾ÝÖÐÐÄÍøÂç

²úÆ·ÌØÕ÷£º

  • ÇáËÉ×éÍø £¬Ö§³Ö32¸ö100G ¶Ë¿Ú £¬ÆäÖÐÓÐ4¸ö¿ÚÖ§³ÖÉýËÙΪ400G½Ó¿Ú £¬²¢Ö§³ÖÏòϲð·Ö40G¡¢25G¡¢10G
  • ¿ç×°±¸Á´Â·¾ÛºÏÊÖÒÕ £¬ÊµÏÖ×°±¸¼¶ÈßÓà £¬ÎÞа×éÍø¿É¿¿ÐÔÇ¿
  • Ö§³ÖVXLANËíµÀÊÖÒÕ £¬Êý¾Ý´«ÊäÎÞÏÞÖÆ £¬×ÊÔ´µ÷Åä¸üÎÞа
  • ¹¹½¨ÎÞËðÒÔÌ«ÍøÂç £¬°ü¹ÜRDMA¶Ëµ½¶ËͨѶÀú³ÌÓªÒµÊý¾Ý²»¶ª°ü
  • TelemetryÍøÂç¼à²â £¬×Ô¶¯»¯ÔËά £¬ÈùÜÀí¼òÆÓ¸ßЧ
Á¬Ã¦×Éѯ

²úÆ·¸ÅÊö

RG-S6501-32CQ ½»Á÷»úÊÇ97¹ú¼ÊÍøÂç×ÔÖ÷Ñз¢µÄÃæÏòÊý¾ÝÖÐÐÄÍÆ³öµÄÐÂÒ»´ú¸ßÐÔÄÜ¡¢¸ßÃÜ¶È 100G ¶Ë¿Ú½»Á÷»ú £¬¾ß±¸ÍêÉÆµÄÊý¾ÝÖÐÐÄÌØÕ÷ ¡£RG-S6501-32CQ ½»Á÷»úµ¥»ú×î´ó¿ÉÌṩ 32 ¸ö 100G ¶Ë¿Ú £¬ÆäÖÐÓÐ4¸ö¿ÚÖ§³ÖÉýËÙΪ400G½Ó¿Ú ¡£

²úÆ·ÌØÕ÷

¹¹½¨ÎÞÛÕ±ÕÊý¾ÝÖÐÐÄÍøÂç £¬Ç¿Ê¢µÄ»º´æÄÜÁ¦

ÃæÏòÏÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÅÌËãµÄ½»Á÷»ú²úÆ·Ïß¾ùΪÏßËÙ²úÆ· £¬ÇкÏÊý¾ÝÖÐÐÄÁ÷Á¿“¹¤¾ß×ßÏò”µÄÉú³¤Ç÷ÊÆ £¬ÊÊÓÃÓÚ´óÁ÷Á¿µÄÏÂÒ»´úÊý¾ÝÖÐÐÄ ¡£

RG-S6501-32CQ½»Á÷»ú¿ÉÌṩ32¸ö100G¶Ë¿Ú £¬ÆäÖÐÓÐ4¸ö¿ÚÖ§³ÖÉýËÙΪ400G½Ó¿Ú ¡£

ͬʱÕë¹ØÓÚÊý¾ÝÖÐÐÄ´óÁ÷Á¿Êý¾ÝÎÞÛÕ±Õ´«ÊäµÄÒªÇó £¬RG-S6501-32CQϵÁн»Á÷»ú¿ÉÒÔÌṩǿʢµÄ»º´æÄÜÁ¦ £¬²¢ÇÒÖ§³ÖÏȽøµÄ»º´æµ÷Àí»úÖÆ £¬¿ÉÒÔ°ü¹Ü×°±¸»º´æÄÜÁ¦µÄÓÐÓÃʹÓà ¡£

Êý¾ÝÖÐÐÄÐéÄâ»¯ÌØÕ÷

Ö§³ÖVSU 2.0£¨Virtual Switch Unit £¬ÐéÄâ½»Á÷µ¥Î»£©ÐéÄ⻯ÊÖÒÕ £¬½«¶ą̀ÎïÀí×°±¸ÐéÄ⻯Ϊһ̨Âß¼­×°±¸ £¬Í³Ò»ÔËÐйÜÀí £¬ïÔÌ­ÍøÂç½Úµã £¬ÔöÌíÍøÂç¿É¿¿ÐÔ ¡£¿ÉʵÏÖ50~200msÁ´Â·¹ÊÕÏ¿ìËÙÇл» £¬°ü¹ÜÒªº¦ÓªÒµ²»ÖÐÖ¹´«Êä ¡£Ö§³Ö¿ç×°±¸Á´Â·¾ÛºÏ £¬Àû±ã½ÓÈë·þÎñÆ÷/½»Á÷»úʵÏÖË«»îÁ´Â·ÉÏÁª ¡£

Êý¾ÝÖÐÐÄOverlayÍøÂç

RG-S6501-32CQ½»Á÷»úÖ§³ÖVXLAN £¬¿ÉÖª×ãÊý¾ÝÖÐÐÄOverlayÍøÂç¹¹½¨ÐèÇó £¬½â¾öÁ˹ŰåÊý¾ÝÖÐÐÄÍøÂçVLANÊýĿȱ·¦ £¬¹æÄ£ÄÑÒÔÀ©Õ¹µÄÎÊÌâ ¡£

RG-S6501-32CQ½»Á÷»ú¼ÜÉèµÄ»ù´¡ÍøÂç £¬¿ÉÒÔÔÚ²»¸Ä±äÎïÀíÍØÆËµÄÇéÐÎÏ £¬»ùÓÚOverlay»®·ÖеÄ×ÓÍø £¬ÎÞÐè˼Á¿ÎïÀíÍøÂçIPµØÖ·ºÍ¹ã²¥ÓòµÄÏÞÖÆ ¡£

Êý¾ÝÖÐÐĶþ²ãÍøÂçÀ©Õ¹

VXLANÊÖÒÕͨ¹ý°Ñ¶þ²ã±¨ÎÄ·â×°ÔÚUDPËíµÀ±¨ÎÄÖеķ½·¨ £¬ÌṩÁËÔÚL3ÍøÂç»ù´¡ÉϹ¹½¨ÁËÒ»¸öÂß¼­ÉϵĶþ²ãÍøÂçµÄÄÜÁ¦ ¡£RG-S6501-32CQ½»Á÷»úÖ§³ÖEVPNЭÒé £¬ÌṩVTEP£¨ËíµÀÖÕ¶Ë£©×Ô¶¯·¢Ã÷ºÍÈÏÖ¤ £¬¿ÉïÔÌ­VXLANÊý¾ÝÃæµÄ·ººé²¢×èÖ¹VXLAN¶Ôµ×²ã°²ÅÅ×é²¥µÄÒÀÀµ £¬¼ò»¯VxLAN°²ÅÅ £¬Ìá¸ß¾þ¶þ²ãÍøÂçµÄ¹¹½¨Ð§ÂÊ £¬¸üºÃµÄÖª×ãÊý¾ÝÖÐÐÄÄÚ²¿µÄ´ó¶þ²ãÍøÂç°²ÅÅÒªÇó ¡£

µçÐż¶¿É¿¿ÐÔÑÚ»¤

RG-S6501-32CQ½»Á÷»úÖ§³ÖµçÔ´ÈßÓà £¬Ö§³ÖÄÚÖÃÈßÓàµçÔ´Ä£¿éºÍÄ£¿é»¯µçÉÈ×é¼þ £¬ËùÓеçÔ´Ä£¿éÒÔ¼°µçÉÈÄ£¿é¾ù¿ÉÒÔÈȲå°Î¶ø²»Ó°Ïì×°±¸µÄÕý³£ÔËÐÐ ¡£±ðµÄÕû»ú»¹Ö§³ÖµçÔ´ºÍµçÉȵĹÊÕϼì²â¼°¸æ¾¯ £¬¿ÉÒÔÆ¾Ö¤Î¶ȵÄת±ä×Ô¶¯µ÷ÀíµçÉȵÄתËÙ £¬¸üºÃµÄ˳ӦÊý¾ÝÖÐÐĵÄÇéÐÎ ¡£»¹¾ß±¸×°±¸¼¶ºÍÁ´Â·¼¶µÄ¶àÖØ¿É¿¿ÐÔÑÚ»¤ ¡£½ÓÄɹýÁ÷ÑÚ»¤¡¢¹ýѹÑÚ»¤ºÍ¹ýÈÈÑÚ»¤ÊÖÒÕ ¡£

³ýÁË×°±¸¼¶¿É¿¿ÐÔÒÔÍâ £¬¸ÃϵÁл¹Ö§³Ö¸»ºñµÄÁ´Â·¿É¿¿ÐÔÊÖÒÕ £¬ºÃ±È¿ìËÙÒÔÌ«ÍøÉÏÁ´ÑÚ»¤Ð­Ò飨REUP £¬Rapid Ethernet Uplink Protection£©Á´Â·¿ìËÙÇл»»úÖÆ ¡£Ö§³ÖGRÍêÉÆÖØÆô¡¢BFD¿ìËÙת·¢¼ì²âµÈ»úÖÆ ¡£µ±ÍøÂçÉϳÐÔØ¶àÓªÒµ¡¢´óÁ÷Á¿µÄʱ¼äÒ²²»Ó°ÏìÍøÂçµÄÊÕÁ²Ê±¼ä £¬°ü¹ÜÓªÒµµÄÕý³£¿ªÕ¹ ¡£

IPv4/IPv6˫ջЭÒé¶à²ã½»Á÷

RG-S6501-32CQ½»Á÷»úÓ²¼þÖ§³ÖIPv4/IPv6˫ЭÒéÕ»¶à²ãÏßËÙ½»Á÷ £¬Ó²¼þÇø·ÖºÍ´¦Öóͷ£IPv4¡¢IPv6ЭÒ鱨ÎÄ £¬Ö§³Ö¶àÖÖTunnelËíµÀÊÖÒÕ£¨ÈçÊÖ¹¤ÉèÖÃËíµÀ¡¢×Ô¶¯ËíµÀºÍ ISATAPËíµÀµÈµÈ£© £¬¿Éƾ֤IPv6ÍøÂçµÄÐèÇóÍýÏëºÍÍøÂçÏÖ×´ £¬ÌṩÎÞаµÄIPv6ÍøÂç¼äͨѶ¼Æ»® ¡£

Ö§³Ö¸»ºñµÄIPv4·ÓÉЭÒé £¬°üÀ¨¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPF¡¢IS-IS¡¢BGP4µÈ £¬Öª×ã²î±ðÍøÂçÇéÐÎÖÐÓû§Ñ¡ÔñºÏÊʵÄ·ÓÉЭÒéÎÞа×é½¨ÍøÂç ¡£

Ö§³Ö¸»ºñµÄIPv6·ÓÉЭÒé £¬°üÀ¨¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+µÈ £¬ÆñÂÛÊÇÔÚÉý¼¶ÏÖÓÐÍøÂçÖÁIPv6ÍøÂç £¬ÕÕ¾Éн¨IPv6ÍøÂç £¬¶¼¿ÉÎÞаѡÔñºÏÊʵÄ·ÓÉЭÒé×é½¨ÍøÂç ¡£

ÎÞаÍêÕûµÄÇå¾²Õ½ÂÔ

RG-S6501-32CQ½»Á÷»ú¾ßÓеĶàÖÖÄÚÔÚ»úÖÆ¿ÉÒÔÓÐÓÃÌá·ÀºÍ¿ØÖƲ¡¶¾Èö²¥ºÍºÚ¿Í¹¥»÷ £¬ÈçÔ¤·ÀDoS¹¥»÷¡¢·ÀºÚ¿ÍIPɨÃè»úÖÆ¡¢¶Ë¿ÚARP±¨ÎĵÄÕýµ±ÐÔ¼ì²é¡¢¶àÖÖÓ²¼þACLÕ½ÂÔµÈ £¬»¹ÍøÂçһƬÂÌÉ« ¡£

Ö§³Ö»ùÓÚÓ²¼þµÄIPv6 ACL £¬×ÝÈ»ÔÚIPv4ÍøÂçÄÚÓÐIPv6Óû§ £¬Ò²¿ÉÇáËÉÔÚÍøÂç±ßÑØÊµÏÖ¶ÔIPv6Óû§µÄ»á¼û¿ØÖÆ £¬¼È¿ÉÔÊÐíÍøÂçÄÚIPv4/IPv6Óû§²¢´æ £¬Ò²¿ÉÒÔ¶ÔIPv6Óû§µÄ»á¼ûȨÏÞ¾ÙÐпØÖÆ £¬ºÃ±ÈÏÞÖÆ¶ÔÍøÂçÃô¸Ð×ÊÔ´µÄ»á¼ûµÈ ¡£

»ùÓÚÔ´IPµØÖ·¿ØÖƵÄTelnet»á¼û¿ØÖÆ £¬×èÖ¹²»·¨Ö°Ô±ºÍºÚ¿Í¶ñÒâ¹¥»÷ºÍ¿ØÖÆ×°±¸ £¬ÔöÇ¿ÁË×°±¸Íø¹ÜµÄÇå¾²ÐÔ ¡£SSH£¨Secure Shell£©ºÍSNMPv3¿ÉÒÔͨ¹ýÔÚTelnetºÍSNMPÀú³ÌÖмÓÃܹÜÀíÐÅÏ¢ £¬°ü¹Ü¹ÜÀí×°±¸ÐÅÏ¢µÄÇå¾²ÐÔ £¬±ÜÃâºÚ¿Í¹¥»÷ºÍ¿ØÖÆ×°±¸ ¡£

¿ØÖƲ»·¨Óû§Ê¹ÓÃÍøÂç £¬°ü¹ÜÕýµ±Óû§ºÏÀí»¯Ê¹ÓÃÍøÂç £¬Èç¶àÔªËØ°ó¶¨¡¢¶Ë¿ÚÇå¾²¡¢Ê±¼äACL¡¢»ùÓÚÊý¾ÝÁ÷µÄ´øÍÑÆÚËÙµÈ £¬Öª×ãÆóÒµÍø¡¢Ð£Ô°ÍøÔöÇ¿¶Ô»á¼ûÕß¾ÙÐпØÖÆ¡¢ÏÞÖÆ·ÇÊÚȨÓû§Í¨Ñ¶µÄÐèÇó ¡£

ÍêÉÆµÄ¹ÜÀíÐÔ

Ö§³Ö¸»ºñµÄ¹ÜÀí½Ó¿Ú £¬ÀýÈçConsole¡¢MGMT¿Ú¡¢USB¿Ú £¬Ö§³ÖSNMPv1/v2c/v3 £¬Ö§³ÖͨÓÃÍø¹Üƽ̨ÒÔ¼°BMCµÈÓªÒµ¹ÜÀíÈí¼þ ¡£Ö§³ÖCLIÏÂÁîÐÐ £¬ Telnet £¬¼¯Èº¹ÜÀí £¬Ê¹×°±¸¹ÜÀí¸üÀû±ã £¬²¢ÇÒÖ§³ÖSSH2.0¡¢SSLµÈ¼ÓÃÜ·½·¨ £¬Ê¹µÃ¹ÜÀíÔ½·¢Çå¾² ¡£

Ö§³ÖSPAN/RSPAN¾µÏñºÍ¶à¸ö¾µÏñÊÓ²ì¶Ë¿Ú £¬¿ÉÒÔ¶ÔÍøÂçÁ÷Á¿¾ÙÐÐÆÊÎöÒÔ½ÓÄÉÏìÓ¦¹ÜÀíά»¤²½·¥ £¬Ê¹Ô­±¾²»¿É¼ûµÄÍøÂçÓªÒµÓ¦ÓÃÁ÷Á¿±äµÃһĿÁËÈ» £¬¿ÉÒÔΪÓû§Ìṩ¶àÖÖÍøÂçÁ÷Á¿ÆÊÎö±¨±í £¬×ÊÖúÓû§ÊµÊ±ÓÅ»¯ÍøÂç½á¹¹ £¬µ÷½â×ÊÔ´°²ÅÅ ¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

¹æ¸ñÃû³Æ RG-S6501-32CQ
²úÆ·³ß´ç£¨¿íxÉîx¸ß£© 442mm x 480mm x 44mm
»ú¼Ü³ß´ç 1U
²úÆ·ÖØÁ¿ 7.7kg£¨¿Õ»úÏ䣩
10.1kg£¨¿Õ»úÏä¡¢2¸öµçÔ´ºÍ4¸öµçÉÈ£©
ÓªÒµ½Ó¿Ú Ö§³Ö32¸ö100G½Ó¿Ú
¹ÜÀí½Ó¿Ú 1¸öRJ45µÄConsole½Ó¿Ú
2¸öRJ45µÄMGMT½Ó¿Ú
USB½Ó¿Ú 1¸öUSB 2.0½Ó¿Ú£¨Type AÅþÁ¬Æ÷£©
Ä£¿é²å²Û 2¸öµçÔ´Ä£¿é²å²Û £¬Ö§³Ö1+1ÈßÓà
4¸öµçÉÈÄ£¿é²å²Û £¬Ö§³Ö3+1ÈßÓà
µçÔ´ÊäÈë RG-PA550I-F£¨ACÊäÈ룩£º
¶î¶¨ÊäÈëµçѹ£º100V AC~240V AC £¬50/60Hz
×î´óÊäÈëµçѹ£º90V~140V AC £¬180V~264V AC £¬47Hz~63Hz
¶î¶¨ÊäÈëµçÁ÷£º7.2A~3.5A£¨100V~240V AC£©
µçÔ´½Ó¿ÚÀàÐÍ£ºC14
RG-PA550I-F£¨HVDCÊäÈ룩£º
¶î¶¨ÊäÈëµçѹ£º240V DC
×î´óÊäÈëµçѹ£º180V~310V DC
¶î¶¨ÊäÈëµçÁ÷£º3.6A
µçÔ´½Ó¿ÚÀàÐÍ£ºC14
ÎÂ¶È ÊÂÇéÇéÐÎζȣº0°C~40°C
´æ´¢ÇéÐÎζȣº-40°C~70°C
˵Ã÷£ºÔÚº£°Î2000~5000Ã×¹æÄ£ÄÚ £¬º£°ÎÿÉý¸ß200Ã× £¬×î¸ßζȹæ¸ñ½µµÍ1¡æ
ʪ¶È ÊÂÇéÇéÐÎʪ¶È£º10%RH~90% RH£¨ÎÞÄý¾Û£©
´æ´¢ÇéÐÎʪ¶È£º5%RH~95%RH£¨ÎÞÄý¾Û£©
º£°Î ÊÂÇ麣°Î£º ≤1800m
´æ´¢º£°Î£º ≤5000m
É¢ÈÈ ·çÀäÉ¢ÈÈ £¬Ç°ºó·çµÀ£¨¶Ë¿Ú²à½ø·ç£©

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S6501-32CQ
L2ЭÒé IEEE802.3ad£¨¾²Ì¬Á´Â·¾ÛºÏ¡¢LACP¡¢¿ç×°±¸Á´Â·¾ÛºÏ£©¡¢IEEE802.1p¡¢IEEE802.1Q¡¢IEEE802.1D£¨STP£©¡¢IEEE802.1w£¨RSTP£©¡¢IEEE802.1s£¨MSTP£©¡¢ERPS¡¢IGMP Snooping v1/v2¡¢MLD Snooping ¡¢Jumbo Frame(9Kbytes)¡¢IEEE802.1ad£¨QinQ¡¢ÎÞаQinQ£©¡¢GVRP¡¢Ö§³ÖAccess¡¢TrunkºÍHybridÈýÖÖģʽ¡¢LLDP¡¢Ö§³Ö¾²Ì¬MACµØÖ·¡¢Ö§³ÖMAC¹ýÂ˵ØÖ·¡¢Ö§³ÖMACµØÖ·ÊýÄ¿ÏÞÖÆ
L3ЭÒ飨IPv4£© ¾²Ì¬Â·ÓÉ¡¢BGP4¡¢OSPFv2¡¢IS-IS¡¢RIPv1¡¢RIPv2¡¢MBGP¡¢LPM Routing¡¢Policy-based Routing¡¢Route-policy¡¢ECMP¡¢WCMP¡¢VRRP¡¢IGMP v1/v2/v3¡¢PIM-SSM/SM/DM¡¢MSDP¡¢Any-RP¡¢BFD for BGP/IS-IS/OSPF/¾²Ì¬Â·ÓÉ¡¢ÊÖ¹¤ËíµÀ¡¢GREËíµÀ
IPv6»ù´¡Ð­Òé ND£¨ÁÚÈË·¢Ã÷£©¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6¡¢ICMPv6¡¢ICMPv6ÖØ¶¨Ïò¡¢ACLv6¡¢TCP/UDP for IPv6¡¢SNMP v6¡¢Ping /Traceroute v6¡¢IPv6 RADIUS¡¢Telnet/SSH v6¡¢FTP/TFTP v6¡¢NTP v6¡¢IPv6 MIB support for SNMP¡¢VRRP for IPv6¡¢IPv6 QoS
IPv6ÌØÕ÷ ¾²Ì¬Â·ÓÉ¡¢µÈ¼Û·ÓÉ¡¢Õ½ÂÔ·ÓÉ¡¢OSPFv3¡¢RIPng¡¢BGP4+¡¢IS-ISv6¡¢IPv6 VRRP ¡¢MLDv1/v2¡¢PIM-SMv6¡¢ÊÖ¹¤ËíµÀ¡¢GREËíµÀ¡¢×Ô¶¯ËíµÀ¡¢IPv4 over IPv6ËíµÀ¡¢ISATAPËíµÀµÈ
Êý¾ÝÖÐÐÄÌØÕ÷ Ö§³ÖVXLAN routingºÍVXLAN bridging
Ö§³ÖEVPN VXLAN£¨»ùÓÚÒÔÌ«ÍøVPNµÄÐéÄâ¿ÉÀ©Õ¹¾ÖÓòÍø£©
Ö§³ÖVXLAN MAPPING
Ö§³ÖIPv4 VXLAN over IPv4
Ö§³ÖIPv6 VXLAN over IPv4
Ö§³ÖIPv4 VXLAN over IPv6
Ö§³ÖIPv6 VXLAN over IPv6
Ö§³ÖM-LAGÌØÕ÷
Ö§³ÖOpenFlow 1.3
Ö§³ÖPFC¡¢ECN
¿ÉÊÓ»¯ Ö§³Ö gRPCͨѶЭÒé
Ö§³Ö sFlow²ÉÑù
Ö§³ÖIPFIX²ÉÑù
QoS Ö§³Ö802.1p¡¢DSCP¡¢ToSµÈÓÅÏȼ¶Ó³Éä £¬Ö§³ÖACLÁ÷·ÖÀà £¬Ö§³ÖÓÅÏȼ¶±ê¼ÇMark/Remark £¬Ö§³ÖSP(PQ)¡¢WRR¡¢DRR¡¢SP(PQ)+WRR¡¢SP(PQ)+DRRµÈ¶àÖÖÐÐÁе÷Àí»úÖÆ £¬Ö§³ÖWRED¡¢Î²ÑïÆúµÈÓµÈû×èÖ¹»úÖÆ¡¢Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ¡¢Ö§³ÖCAR
ÐéÄ⻯ Ö§³ÖVSU£¨ÐéÄ⻯ÊÖÒÕ £¬½«¶ą̀װ±¸ÐéÄâ³É1̨£©
»º´æ¹ÜÀí Ö§³Ö»º´æ×´Ì¬¼à¿Ø¼°¹ÜÀí £¬Ê¶±ðÁ÷Á¿Î¢Í»·¢ÇéÐÎ
¸ß¿É¿¿Éè¼Æ Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓÉЭÒé¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖDLDP¡¢Ö§³ÖREUPË«Á´Â·¿ìËÙÇл»ÊÖÒÕ¡¢Ö§³ÖRLDPµ¥ÏòÁ´Â·¼ì²âÊÖÒÕ¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÉȽÓÄÉÈßÓàÉè¼Æ¡¢ËùÓе¥°åºÍµçÔ´Ä£¿éÖ§³ÖÈȲå°Î¹¦Ð§¡¢Ö§³ÖVRRP¡¢VRRP¸ºÔØ·Öµ£/Ë«»î¡¢BFD for VRRP
Çå¾²¹¦Ð§ »ù´¡ÍøÂçÑÚ»¤Õ½ÂÔ£¨NFPP £¬Network Foundation Protection Policy£©¡¢CPP¡¢·ÀDDoS/DoS¹¥»÷¡¢·ÀICMP¹¥»÷¡¢²»·¨Êý¾Ý°ü¼ì²â¡¢Êý¾Ý¼ÓÃÜ¡¢·ÀÔ´IPÓÕÆ­¡¢·ÀIPɨÃè¡¢Ö§³ÖRADIUS/TACACS¡¢Ö§³Ö»ùÓÚ±ê×¼¡¢À©Õ¹¡¢VLAN µÄIPv4/v6 ACL±¨ÎĹýÂË¡¢Ö§³ÖOSPF¡¢RIPv2 ¼°BGPv4 ±¨ÎĵÄÃ÷Îļ°MD5ÃÜÎÄÈÏÖ¤¡¢Ö§³ÖÊÜÏÞµÄIPµØÖ·µÄTelnetµÄµÇ¼ºÍ¿ÚÁî»úÖÆ¡¢uRPF¡¢Ö§³Ö¹ã²¥±¨ÎÄÒÖÖÆ¡¢DHCP Snooping¡¢·ÀÍø¹ØARPÓÕÆ­(·ÀARP¹¥»÷)¡¢ARP Check £¬Ö§³ÖÓû§·Ö¼¶¹ÜÀí
¹ÜÀí·½·¨ SNMP v1/v2c/v3¡¢Telnet¡¢Console¡¢MGMT¡¢RMON¡¢SSHv1/v2¡¢FTP/TFTPÎļþÉÏÏÂÔØ¹ÜÀí¡¢Ö§³ÖNTPʱÖÓ¡¢Ö§³ÖSyslog¡¢Ö§³ÖSPAN/RSPAN/ERSPAN¡¢Ö§³ÖTelemetry £¬Ö§³ÖZTP¡¢Ö§³ÖNETCONF¡¢Ö§³ÖPython¡¢Ö§³ÖµçÉÈ¡¢µçÔ´¸æ¾¯ÒÔ¼°Î¶ÈÒì³£¸æ¾¯¡¢Ö§³ÖÉèÖûعö
ÆäËüЭÒé DHCP Client¡¢DHCP Relay¡¢DHCP Server¡¢DNS Client¡¢UDP relay¡¢ARP Proxy¡¢Syslog

* ÌåÏÖδÀ´Ö§³ÖÌØÕ÷ ¡£

Õö¿ªÏêϸ²ÎÊý

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌâ £¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ ¡£©£¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ ¡£©£¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ £¬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À ¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼