128¿Ú200GÊý¾ÝÖÐÐĺÐʽ½¹µã½»Á÷»ú £¬4U¸ß¶È £¬RG-S6980-128DC

ÃæÏòAI¡¢´óÊý¾Ý¡¢¸ßÐÔÄÜÅÌËã¡¢ÂþÑÜʽ´æ´¢µÈÓ¦ÓÃÉú³¤Ç÷ÊÆÍÆ³öµÄÐÂÒ»´ú¸ßÐÔÄÜ¡¢¸ßÃܶȺÐʽ½»Á÷»ú

²úÆ·ÌØÕ÷£º

  • ¸ßÃܶÈ200G½»Á÷»ú £¬4U¸ß¶È¿Õ¼äÄÚ £¬128¸ö200G QSFP56¶Ë¿Ú
  • Ó²¼þ¼¶ÈßÓà±£»¤ £¬°ü¹ÜÓªÒµÒ»Á¬ÐÔ £¬ÍøÂç²»ÖÐÖ¹
  • RDMA¶Ëµ½¶ËÊý¾Ýת·¢ £¬¹¹½¨ÎÞËðÍøÂç £¬Êý¾Ý´«Êä²»¶ª°ü
  • TelemetryÍøÂç¼à²â £¬×Ô¶¯»¯ÔËά £¬ÈùÜÀí¼òÆÓ¸ßЧ
Á¬Ã¦×Éѯ

Êý¾ÝÖÐÐÄ200G½¹µã½»Á÷»ú RG-S6980-128DC

Êý¾ÝÖÐÐĸßËÙ¡¢¸ßÃܽ¹µã×°±¸ £¬4U¿Õ¼äÄÚÓÐ128¸ö200G QSFP56¶Ë¿Ú
Ìṩ¿ÉÀ©Õ¹¡¢¸ßÐÔÄܼ°´ó´ø¿í·þÎñ £¬Öª×ã´óÐÍÊý¾ÝÖÐÐÄÍøÂ绥ÁªÐèÇó
¿´¶Ë¿Ú
¿´³ß´ç

Ó²¼þ¼¶ÈßÓà±£»¤ £¬°ü¹ÜÓªÒµÒ»Á¬ÐÔ £¬ÍøÂç²»ÖÐÖ¹

ÈȲå°ÎÈßÓàµçÔ´
ÈȲå°ÎÈßÓàµçÉÈ
2+2µçÔ´ÈßÓà £¬¹ÊÕÏÃëÇл» £¬Ìæ»»µçÔ´Ò»Ö±Íø £¬ÎªÁ´Â·Ìá¹©Ë«ÖØ±£»¤

¹¹½¨ÎÞËðÒÔÌ«ÍøÂç £¬°ü¹ÜRDMA¶Ëµ½¶ËͨѶÀú³ÌÓªÒµÊý¾Ý²»¶ª°ü

RDMAÔ¶³ÌÖ±½ÓÄÚ´æ»á¼ûÊÖÒÕ £¬×°±¸Í¨Ñ¶Ê± £¬Êý¾ÝÎÞÐè¾­ÓÉCPU´¦Öóͷ£ £¬¼õÇáCPU¼ç¸º £¬ÓÐÓýâ¾öÍøÂçÑÓ³ÙÎÊÌâ
PFC+ECNÊÖÒÕ £¬Êý¾ÝÖÇÄܽ»»¥ £¬·À¶ª°ü £¬°ü¹ÜÍøÂçÊý¾ÝÎÞËð´«Êä

TelemetryÍøÂç¼à²â £¬×Ô¶¯»¯ÔËά £¬ÈùÜÀí¼òÆÓ¸ßЧ

½ÓÄÉTelemetryÍøÂç¼à²âÊÖÒÕ £¬Êý¾Ý״̬¡¢ÌõÀí»¯¸üÇåÎú
ͨ¹ý“ÍÆÄ£Ê½”×Ô¶¯ÊÕÂÞÓëÍÆËÍÐÅÏ¢ £¬ÊµÊ±ÌṩÑÇÃë¼¶ÍøÂç¼à²â £¬ÍøÂç¹ÜÀí¸ßЧ¸ü¾«×¼
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿

²»Õ¦µÎ ºÜÊǺÃ

Äú¸ø³ö¸Ã·ÖÊýµÄÖ÷ÒªÔµ¹ÊÔ­ÓÉÊÇʲô£¿

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû ¡£

97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿
²»Õ¦µÎ ºÜÊǺÃ

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû ¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

¹æ¸ñÃû³Æ RG-S6980-128DC
²úÆ·³ß´ç£¨¿íxÉîx¸ß£© 442mm x 760mm x 175mm
»ú¼Ü³ß´ç 4U
²úÆ·ÖØÁ¿ 39.65kg£¨¿Õ»úÏä¡¢4¸öµçÔ´ºÍ8¸öµçÉÈ£©
½»Á÷ÈÝÁ¿ 51.2Tbps
°üת·¢ÂÊ 10300Mpps
ÓªÒµ½Ó¿Ú 128¸ö100G/200G QSFP56½Ó¿Ú
¹ÜÀí½Ó¿Ú 1¸öRJ45µÄConsole½Ó¿Ú
1¸öRJ45µÄMGMT½Ó¿Ú
USB½Ó¿Ú 1¸öUSB 2.0½Ó¿Ú£¨Type AÅþÁ¬Æ÷£©
Ä£¿é²å²Û 4¸öµçÔ´Ä£¿é²Ûλ
8¸öµçÉÈÄ£¿é²Ûλ
Õû»ú¹¦ºÄ ×î´ó¹¦ºÄ£º2550W
µä·¶¹¦ºÄ£º1800W
¾²Ì¬¹¦ºÄ£º250W
µçÔ´ÊäÈë PSA1300CRPS-F-RJ£¨ACÊäÈ룩£º
¶î¶¨ÊäÈëµçѹ£º100V~127V AC £¬200V~240V AC £¬50/60Hz
×î´óÊäÈëµçѹ£º90V~140V AC £¬180V~264V AC £¬47Hz~63Hz
¶î¶¨ÊäÈëµçÁ÷£º12A£¨100V~127V AC£©
8A £¨200V~240V AC£©
µçÔ´½Ó¿ÚÀàÐÍ£ºC14
PSA1300CRPS-F-RJ£¨HVDCÊäÈ룩£º
¶î¶¨ÊäÈëµçѹ£º240V DC£¨½öÏÞÖйúµØÇøÊ¹Óã©
×î´óÊäÈëµçѹ£º180V~310V DC
¶î¶¨ÊäÈëµçÁ÷£º6.5A
µçÔ´½Ó¿ÚÀàÐÍ£ºC14
ÎÂ¶È ÊÂÇéÇéÐÎζȣº0¡ãC~40¡ãC
´æ´¢ÇéÐÎζȣº-40¡ãC~70¡ãC
˵Ã÷£ºÔÚº£°Î1800~5000Ã×¹æÄ£ÄÚ £¬º£°ÎÿÉý¸ß200Ã× £¬×î¸ßζȹæ¸ñ½µµÍ1¡æ
ʪ¶È ÊÂÇéÇéÐÎʪ¶È£º10%RH~90% RH£¨ÎÞÄý¾Û£©
´æ´¢ÇéÐÎʪ¶È£º5%RH~95%RH£¨ÎÞÄý¾Û£©
º£°Î ÊÂÇ麣°Î£º¡Ü5000m
´æ´¢º£°Î£º¡Ü5000m
É¢ÈÈ ·çÀäÉ¢ÈÈ £¬Ç°ºó·çµÀ£¨¶Ë¿Ú²à½ø·ç£©

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S6980-128DC
L2ЭÒé IEEE802.3ae£¨10GBase£©¡¢IEEE802.3ak¡¢IEEE802.3an ¡¢IEEE802.3x¡¢IEEE802.3ad£¨Á´Â·¾ÛºÏ£©¡¢IEEE802.1p¡¢IEEE802.1Q¡¢IEEE802.1D£¨STP£©¡¢IEEE802.1w£¨RSTP£©¡¢IEEE802.1s£¨MSTP£©¡¢Jumbo Frame(9Kbytes)
IPv4ÌØÕ÷ BGP4¡¢OSPFv2¡¢RIPv1¡¢RIPv2¡¢LPM Routing¡¢Policy-based Routing¡¢Route-policy¡¢ECMP¡¢WCMP¡¢VRRP
IPv6ÌØÕ÷ ND£¨ÁÚÈË·¢Ã÷£©¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6¡¢ICMPv6¡¢ICMPv6ÖØ¶¨Ïò¡¢ACLv6¡¢TCP/UDP for IPv6¡¢SNMP v6¡¢Ping /Traceroute v6¡¢IPv6 RADIUS¡¢Telnet/SSH v6¡¢FTP/TFTP v6¡¢NTP v6¡¢IPv6 MIB support for SNMP¡¢VRRP for IPv6¡¢IPv6 QoS¡¢¾²Ì¬Â·ÓÉ¡¢µÈ¼Û·ÓÉ¡¢Õ½ÂÔ·ÓÉ¡¢OSPFv3¡¢RIPng¡¢BGP4+µÈ
Êý¾ÝÖÐÐÄÌØÕ÷ Ö§³ÖPFC¡¢ECNµÈÊý¾ÝÖÐÐÄÌØÕ÷
Ö§³Ö RDMAÌØÕ÷
Ö§³ÖVXLAN¡¢BGP-EVPN
Ö§³ÖPFCËÀËøÔ¤·À
* Ö§³ÖAI ECN
* Ö§³ÖECN overlay
Ö§³ÖÈ«¾Ö¸ºÔØÆ½ºâRALB¡¢AILBÊÖÒÕ
¿ÉÊÓ»¯ Ö§³ÖTelemetry £¬ÊÕÂÞ½»Á÷»ú»ù´¡ÐÅÏ¢ £¬RoCEÏà¹ØµÄ»º´æÊµÊ±×´Ì¬¡¢½Ó¿ÚQoSÐÐÁкͽӿÚʹÓÃÂÊʵʱ״̬¡¢ECNºÍPFCµÈÒªº¦ÊÂÎñ £¬¹âÄ£¿éMedia Side SNR*
Ö§³Ö GRPCͨѶЭÒé
Ö§³Ö sFLOW¸ß¾«¶È²ÉÑù
QoS Ö§³Ö802.1p¡¢DSCP¡¢ToSµÈÓÅÏȼ¶Ó³Éä £¬Ö§³ÖACLÁ÷·ÖÀà £¬Ö§³ÖÓÅÏȼ¶±ê¼ÇMark/Remark £¬Ö§³ÖSP¡¢WRR¡¢WFQ¡¢DRR¡¢SP+WRR¡¢SP+WFQ¡¢SP+DRRµÈ¶àÖÖÐÐÁе÷Àí»úÖÆ £¬Ö§³ÖWRED¡¢Î²ÑïÆúµÈÓµÈû×èÖ¹»úÖÆ
¸ß¿É¿¿Éè¼Æ Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓÉЭÒé¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖDLDP¡¢Ö§³ÖREUPË«Á´Â·¿ìËÙÇл»ÊÖÒÕ¡¢Ö§³ÖRLDPµ¥ÏòÁ´Â·¼ì²âÊÖÒÕ¡¢Ö§³ÖµçÔ´2+2ÈßÓ౸·Ý¡¢µçÉȽÓÄÉÈßÓàÉè¼Æ¡¢ËùÓе¥°åºÍµçÔ´Ä£¿éÖ§³ÖÈȲå°Î¹¦Ð§
Çå¾²¹¦Ð§ »ù´¡ÍøÂç±£»¤Õ½ÂÔ£¨NFPP £¬Network Foundation Protection Policy£©¡¢CPP¡¢Ö§³ÖRADIUS/TACACS¡¢Ö§³Ö»ùÓÚ±ê×¼¡¢À©Õ¹¡¢VLAN µÄIPv4/v6 ACL±¨ÎĹýÂË¡¢Ö§³ÖOSPF¡¢RIPv2 ¼°BGPv4 ±¨ÎĵÄÃ÷Îļ°MD5ÃÜÎÄÈÏÖ¤¡¢Ö§³ÖÊÜÏÞµÄIPµØÖ·µÄTelnetµÄµÇ¼ºÍ¿ÚÁî»úÖÆ¡¢Ö§³Ö¹ã²¥±¨ÎÄÒÖÖÆ¡¢Ö§³ÖÓû§·Ö¼¶¹ÜÀí
¹ÜÀí·½·¨ SNMP v1/v2c/v3¡¢Telnet¡¢Console¡¢MGMT¡¢RMON¡¢SSHv1/v2¡¢FTP/TFTPÎļþÉÏÏÂÔØ¹ÜÀí¡¢Ö§³ÖNTPʱÖÓ¡¢Ö§³ÖSyslog¡¢Ö§³ÖSPAN/RSPAN/ERSPAN¡¢Ö§³ÖZTP¡¢Ö§³ÖNETCONF¡¢Ö§³ÖPython¡¢Ö§³ÖµçÉÈ¡¢µçÔ´¸æ¾¯ÒÔ¼°Î¶ÈÒì³£¸æ¾¯
ÆäËüЭÒé DHCP Client¡¢DHCP Relay¡¢DHCP Server¡¢DNS Client¡¢ARP Proxy¡¢Syslog

*ÌåÏÖδÀ´Ö§³ÖÌØÕ÷

Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
²úÆ·´îÅä(1)
Íõ**** 2024Äê05ÔÂ13ÈÕ
RG-S6980-128DC½»Á÷»ú°üÀ¨ÄÄЩÅä¼þ£¿
ÓÐÓÃ 0 ÎÞÓÃ 0
RG-S6980-128DCºÐʽ½»Á÷»úÕû»ú°üÀ¨Ö÷»ú¡¢µçÔ´¼°µçÉÈ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ ¡£©£¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ ¡£©£¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ £¬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À ¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼