97¹ú¼Ê

Àë±ðÔËάÄÚÚ§ È«ÓòЭͬÌáЧ Ø­ 97¹ú¼ÊÍøÂçÔËά°ü¹ÜÂÄÀú·ÖÏí»á
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-S12006
RG-S12006
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

RG-S12006

RG-S12006

ÀàÐÍ£º

²úÆ·ÌØÕ÷£º

Á¬Ã¦×Éѯ

ͳһ½»Á÷£¬Èںϴ洢ÓëÒÔÌ«Íø

RG-S12000 Cloud ComputingϵÁÐÃæÏòÏÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÅÌËãµÄ½»Á÷»ú²úÆ·Ïß¿ÉΪ·þÎñÆ÷ÌṩFCoE£¨Fibre Channel over Ethernet£©½ÓÈëºÍÒÔÌ«Íø½ÓÈë·þÎñ£¬´Ó¶ø×ÊÖúÓû§ÇáËÉÕûºÏÒì¹¹µÄ´æ´¢ÍøºÍÊý¾ÝÍø£¬ïÔÌ­ÍøÂçÖеÄ×°±¸ÊýÄ¿£¬¼ÈÄÜÕæÕýʵÏÖÊý¾ÝÖÐÐÄÍøÂç¼Ü¹¹µÄÈںϣ¬ÓÖÄܳä·Ö±£»¤Óû§ÒÑÓÐͶ×Ê¡£

¹¹½¨ÎÞÛÕ±ÕÊý¾ÝÖÐÐÄ

RG-S12000 Cloud ComputingϵÁУ¨½¹µã£©+ RG-S6200ϵÁУ¨ÍòÕ×½ÓÈ룩+RG-S6000£¨Ç§Õ×½ÓÈ룩ϵÁй¹½¨´Ó½ÓÈëµ½½¹µãÕæÕýÎÞÛÕ±ÕµÄÊý¾ÝÖÐÐÄÍøÂ磨Clos Network£¬ÆðÔ´£º±´¶ûʵÑéÊÒClosÏÈÉúÉè¼Æ£¬ÓÃÓÚµç»°ÍøÂ磬ʵÏÖÎÞÛÕ±Õ½»Á÷¡£Clos NetworkµÄÕæÕý¼ÄÒåÊÇʵÏÖÕûÍøµÄÎÞÛÕ±Õ£¬¶ø·Ç¼òµ¥µÄ»ùÓÚij¸ö²úÆ·µÄÎÞÛÕ±Õ¡££©

RG-S12000 Cloud ComputingϵÁÐÔÚÒµÄÚÂÊÏÈÖ§³Ö40GºÍ100G±ê׼ģ¿é£¬½«40G/100GÕæÕýÂ䵨£¬×ÊÖúÓû§×é½¨ÃæÏòÔÆÅÌËãµÄÐÂÒ»´úÊý¾ÝÖÐÐÄÎÞÛÕ±Õ½»Á÷ÍøÂç¡£

ÖÜÈ«µÄÊý¾ÝÖÐÐÄÐéÄâ»¯ÌØÕ÷

Ö§³ÖÒµ½çÁìÏȵÄVSU2.0ÐéÄ⻯ÊÖÒÕ£¬½«¶ą̀ÎïÀí×°±¸ÐéÄ⻯Ϊһ̨Âß¼­×°±¸£¬Í³Ò»ÔËÐйÜÀí£¬´ó·ùïÔÌ­ÍøÂç½Úµã£¬½µµÍÍøÂçÔËά¹ÜÀíÖ°Ô±ÊÂÇéÁ¿¡£ÔöÌíÍøÂç¿É¿¿ÐÔ£¬ÊµÏÖ50~200msÁ´Â·¹ÊÕÏ¿ìËÙÇл»£¬°ü¹ÜÒªº¦ÓªÒµ²»ÖÐÖ¹´«Êä¡£Ö§³Ö¿ç×°±¸Á´Â·¾ÛºÏ£¬Àû±ã½ÓÈë·þÎñÆ÷/½»Á÷»úʵÏÖË«»îÁ´Â·ÉÏÁª£¬ÍøÂçÓÐÓÃÅþÁ¬´ø¿í³É±¶ÔöÌí¡£

97¹ú¼ÊÍøÂ绹¶ÔÒѳÉÊìÓ¦ÓõÄVSUÐéÄ⻯ÊÖÒÕ¾ÙÐдó·ùÊÖÒÕÉý¼¶£ºËùÓиßÐÔÄܽӿÚÏß¿¨É϶¼¼¯³ÉÁËרÓÃVSUÓ²¼þ´¦Öóͷ£µç·£¬²¢¾ß±¸½¨ÉèVSL£¨Virtual Switching Link£¬ÐéÄâ½»Á÷Á´Â·£©ÄÜÁ¦£¬ÌáÉýÓû§Ñ¡Åä×°±¸ÎÞаÐÔ£»VSL×î´óÁ´Â·´ø¿íµÖ´ï2.56T£¬¸ß¾ÓÒµ½çµÚÒ»£¬³¹µ×Ïû³ýÐéÄâ½»Á÷³ÉÔ±¼ä´ø¿íÆ¿¾±¡£

Ö§³ÖVRFÐéÄâ»¯ÌØÕ÷£¬ÊµÏÖÊý¾ÝÖÐÐÄÍøÂçÒ»±ä¶à£¬°ü¹Ü¶àÓªÒµÇå¾²¸ôÀë¡£

Ö§³ÖIEEE802.1Qbg±ê×¼½ç˵µÄVEPA£¨Virtual Ethernet Port Aggregator£¬ÐéÄâÒÔÌ«Íø¶Ë¿Ú¾ÛºÏ£©£¬Äܹ»½«·þÎñÆ÷ÐéÄâ»ú±¬·¢µÄÊý¾ÝÁ÷Ç£Òýµ½ÎïÀíÍøÂç×°±¸ÉϾÙÐГӲ½»Á÷”£¬ÈÃÐéÄâ»ú½»Á÷¹¦Ð§ÖØÐÂ»Ø¹éµ½ÍøÂç×°±¸£¬¼È½â¾öÁËÐéÄâ»úÁ÷Á¿ÎÞ·¨î¿Ïµ¡¢»á¼û¿ØÖÆÕ½ÂÔÎÞ·¨Í³Ò»°²ÅŵÈÎÊÌ⣬ÓÖÏû³ý¹Å°å“Èí½»Á÷”¶Ô·þÎñÆ÷×ÊÔ´µÄÕ¼Óã¬Ê¹ÏÂÒ»´úÊý¾ÝÖÐÐÄÍøÂç½â¾ö¼Æ»®¸üºÃ˳ӦÐéÄ⻯ÅÌËãÇéÐΡ£

Ö§³ÖÐéÄâ»ú¸ÐÖª¼°Çå¾²Õ½ÂÔ×Ô¶¯Ç¨á㣬ÓÐÓÃʵÏÖ´ó¹æÄ£·þÎñÆ÷ÐéÄ⻯ӦÓÃÇéÐÎÖÐÐéÄâ»úÁ÷Á¿µÄÇå¾²¿ØÖÆÕ½ÂÔͳһ°²ÅÅ£¬²¢Í¨¹ýÊý¾ÝÖÐÐÄÍøÂç¹ÜÀíÆ½Ì¨ÅäºÏÊý¾ÝÖÐÐĽ»Á÷»ú¡¢ÐéÄâ»ú¹ÜÀí¿ØÖÆÆ½Ì¨£¬ÊµÏÖÐéÄâÖ÷»úÈ«Íø¹æÄ£ÄÚ×ÔÓÉǨáãʱ¶ÔÓ¦Çå¾²¿ØÖÆÕ½ÂÔµÄͬ²½Ç¨á㣬Ïû³ý·þÎñÆ÷ÐéÄ⻯ÇéÐÎÖÐÍøÂçÇå¾²Îó²î£¬ïÔÌ­ÍøÂçά»¤ÊÂÇéÁ¿¡£

¹¹½¨TRILL͸Ã÷½»Á÷ÍøÂ磬ΪÐéÄâ»¯ÔÆÅÌËãµÓÚ¨»ù´¡

Éú³¤ÖеÄÊý¾ÝÖÐÐÄÖÁÉÙÒªÃæÁÙÈý¸öÍøÂç·½ÃæµÄÌôÕ½£º¸ü´óµÄ´ø¿í¡¢¸üÎÞаµÄ×éÍøºÍ¸ü¼òÆÓµÄ¹ÜÀí¡£IETF×îÐÂÖÆ¶©µÄTRILL£¨Transparent Interconnection of Lots of Links£¬¶àÁ´½Ó͸Ã÷»¥Áª£©±ê׼ЭÒ飬±ãÒ»¾Ù½â¾öÁËÕâÈý¸öÎÊÌâ¡£

TRILLÒýÈëÀàËÆIS-ISµÄ·ÓÉ»úÖÆ£¬¶þ²ãÊý¾Ý±¨Îİ´×î¶Ì·¾¶×ª·¢£¬²¢ÒýÈëTTLÏû³ýÍøÂçÄÚ¶þ²ã»·Â·£¬´ó·ùÔöÌíÍøÂçÎȹÌÐÔ¡£Êý¾ÝÖÐÐÄÄÚʹÓÃTRILLЭÒéʵÏÖ³¬´ó¹æÄ£¶þ²ã×éÍø£¬¿ÉÌáÉýÓû§ÓªÒµ°²ÅÅÎÞаÐÔ£¬²¢À©´óÐéÄâ»úǨáã¹æÄ£¡£

TRILL×éÍøÏ£¬ËùÓÐÊý¾ÝÁ÷Á¿»ùÓÚSPF¼°ECMPʵÏÖ¿ìËÙת·¢£¬½â¾ö¹Å°åSTPЭÒéÖб£´æµÄ´ÎÓÅ·¾¶ÎÊÌ⣬²¢ÇÒ²»ÛÕ±ÕÈκζ˿Ú£¬´ø¿íʹÓÃÂÊÌáÉýÖÁ100%¡£

°üÀ¨RG-S12000ϵÁÐÔÚÄÚ£¬97¹ú¼ÊÍøÂçÈ«ÏßÐÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÅÌËã½»Á÷»ú²úÆ·¾ùÓ²¼þоƬ֧³ÖTRILLЭÒ飬ȫÏß²úƷͨ¹ýTRILLЭÒéͨѶ£¬¿ÉÓÐÓüò»¯ÍøÂçÉè¼Æ£¬Ìá¸ßÍøÂç¿ÉÀ©Õ¹ÐԺ͵¯ÐÔ£¬²¢Îª¹¹½¨Ò»¸ö´óÐ͵ÄÐéÄâ»¯ÔÆÅÌËãÍøÂçµÓÚ¨»ù´¡¡£

ÂÌÉ«»·±£Éè¼Æ

RG-S12000ϵÁÐÖ§³Ö¶ÔµçÔ´µÄÖÇÄܹÜÀí¹¦Ð§£¬²¢½ÓÄÉÁË ¸ßЧµÄµçԴϵͳ¼Ü¹¹Éè¼Æ£¨DC-DCµçԴת»»Ä£¿é£©ÊµÏָߴï95%µÄµçԴת»»Ð§ÂÊÓÐÓýÚÄÜ¡£¶ÀÍ̵ĵçÔ´¼à¿Ø¹¦Ð§£¬°ü¹ÜÓû§¿Éƾ֤ÏÖʵʹÓÃ״̬°´Ðè×°ÖõçÔ´£»¿ÉÒÔÖ§³Öµ¥°å˳ÐòÉϵ磨½µµÍµ¥°åͬʱÉÏµç´øÀ´µÄµçÔ´¹¥»÷£¬Ìá¸ß×°±¸ÊÙÃü£¬½µµÍµç´Å·øÉ䣩£¬¿ÉÒÔ¿ØÖƵ¥°åϵ磬¸ôÀë¹ÊÕÏ/¿ÕÏе¥°å£¬½µµÍϵͳ¹¦ºÄ¡£

ÖÇÄܵçÉÈÉè¼Æ£¬½ÓÄɸßЧµÄοص÷ËÙµçÉÈ£¬Ö§³ÖÎÞ¼¶µ÷ËÙ¡£ÏµÍ³¿ÉÒÔ×Ô¶¯ÍøÂçµ¥°åζÈ£¬Æ¾Ö¤×°±¸ÏÖÕæÏàÐÎÅÌËãµçÉȵ÷ËÙÇúÏߣ¬²¢½«µ÷ËÙÏÂÁîÏ·¢µ½µçÉÈ¿ò¡£ÏµÍ³Ö§³ÖµçÉÈ״̬¼à¿Ø£¨×ªËÙ¼à¿Ø¡¢¹ÊÕϸ澯µÈ£©¿ÉÒÔÆ¾Ö¤ÇéÐÎζȡ¢µ¥°åÉèÖÃ×Ô¶¯·ÖÇøµ÷ËÙ£¬½µµÍ×°±¸¹¦ºÄºÍÔËÐÐÔëÉù£¬ÓÐÓýµµÍÇéÐÎÔëÒô²¢ÑÓÉìµçÉÈÊÙÃü¡£

RG-S12000ϵÁÐÖ§³ÖÄÚ²¿¶Ë¿ÚµÄ×Ô¶¯¼ì²â£¬µ±Ä³²ÛλδÉèÖýӿڰåʱ£¬»òÕß¶Ë¿ÚδÅþÁ¬ÏßÀÂʱ¼ä£¬ÏµÍ³¿ÉÒÔ×Ô¶¯¹Ø±ÕÏìÓ¦µÄÄÚ²¿¶Ë¿Ú£¬½ÚÔ¼ÁËÕû»ú¹¦ºÄ¡£½ÓÄɳ¬µÍ¹¦ºÄоƬ£¬Êý¾ÝÖÐÐĽ»Á÷»úϵÁн»Á÷»úÔÚоƬѡÔñʱ£¬´ó¶¼½ÓÄÉ65nm¹¤ÒÕÉè¼ÆµÄоƬ£¬Ïà±È¹Å°å½»Á÷»ú£¬½ÚÔ¼20%ÒÔÉϵÄÄܺÄ¡£

µçÐż¶¿É¿¿ÐÔ±£»¤

1. ÎÞµ¥µã¹ÊÕÏÉè¼Æ

½ÓÄÉÎÞÔ´±³°å×èÖ¹»úÏä·ºÆðµ¥µã¹ÊÕÏ£»ËùÓÐÒªº¦Æ÷¼þ£¬ÈçÒýÇæ¡¢µçÔ´¡¢µçÉȺÍCrossbarµÈ¾ù½ÓÄÉÈßÓàÉè¼Æ£»Ë«ÒýÇæÇл»Ê±ÊµÏÖÍòÕ×Êý¾ÝÓªÒµ²»ÖÐֹת·¢£¬ÓÐÓðü¹ÜÍøÂçÎȹÌ¡£ËùÓе¥°åºÍµçÔ´Ä£¿éÖ§³ÖÈȲå°Î¹¦Ð§£¬²¢ÇÒ¶ÔÆäËüµ¥°åÉÏÔËÐеÄÓªÒµÎÞÓ°Ïì¡£

Ö§³ÖµçÔ´ÈßÓ֧࣬³ÖÄÚÖÃÈßÓàµçÔ´Ä£¿éºÍÄ£¿é»¯µçÉÈ×é¼þ£¬ËùÓнӿڰ壬µçÔ´Ä£¿éÒÔ¼°µçÉÈÄ£¿é¾ù¿ÉÒÔÈȲå°Î¶ø²»Ó°Ïì×°±¸µÄÕý³£ÔËÐС£±ðµÄÕû»ú»¹Ö§³ÖµçÔ´ºÍµçÉȵĹÊÕϼì²â¼°¸æ¾¯£¬¿ÉÒÔÆ¾Ö¤Î¶ȵÄת±ä×Ô¶¯µ÷ÀíµçÉȵÄתËÙ£¬¸üºÃµÄ˳ӦÊý¾ÝÖÐÐĵÄÇéÐΡ£»¹¾ß±¸×°±¸¼¶ºÍÁ´Â·¼¶µÄ¶àÖØ¿É¿¿ÐÔ±£»¤¡£½ÓÄɹýÁ÷±£»¤¡¢¹ýѹ±£»¤ºÍ¹ýÈȱ£»¤ÊÖÒÕ¡£

2. µ¯ÐÔÒÔÌ«ÍøÊÖÒÕ

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖRERPÊÖÒÕ£¨¿ìËÙÒÔÌ«Íø»·±£»¤Ð­Ò飩£¬ÈÚºÏÁËSDH¹ÊÕÏ×ÔÓúµÄ¸ß¿É¿¿ÐÔÓëÒÔÌ«ÍøµÄ¾­¼ÃÐÔ¡¢¸ß´ø¿íµÈÓÅÊÆ£¬ÔÚRERPÍøÂçÉÏÀ©Õ¹Ö§³ÖIPv4/IPv6·ÓÉЭÒé¡¢MPLS¹¦Ð§£¬¿ÉÒÔ°ü¹ÜÍòÕ×ÏßËÙÓªÒµÇéÐÎÏÂСÓÚ50msµÄ¹ÊÕÏÇл»Ê±¼ä£¬°ü¹ÜÓïÒô¡¢ÊÓÆµµÈʵʱӪҵ²»ÊÜÍøÂçÊÕÁ²Ó°Ïì¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖREUPÊÖÒÕ£¬ÔÚÀ©Õ¹Ö§³ÖIPv4/IPv6·ÓÉЭÒé¡¢MPLS¹¦Ð§µÄÇéÐÎÏ£¬°ü¹ÜË«Á´Â·ÉÏÁªÍøÂçÍØÆËµÄÓªÒµºÁÃë¼¶¿ìËÙÇл»¡£µ±ÍøÂçÉϳÐÔØ¶àÓªÒµ¡¢´óÁ÷Á¿µÄʱ¼äÒ²²»Ó°ÏìÍøÂçµÄÊÕÁ²Ê±¼ä£¬°ü¹ÜÓªÒµµÄÕý³£¿ªÕ¹¡£

3. ·ÓÉЭÒéµÄ¸ß¿É¿¿°ü¹Ü

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖOSPF/IS-IS/BGPµÄÓÅÑÅÖØÆôÊÖÒÕ£¨Graceful Restart£©£¬ÌṩºÁÃë¼¶µÄÇл»Ê±¼ä£»Ö§³ÖECMP/WCMP£¬¿É×ÊÖúÓû§Ê¹ÓöàÌõÁ´Â·£¬²»µ«ÔöÌíÁË´«Êä´ø¿í£¬²¢ÇÒ¿ÉÒÔÎÞʱÑÓÎÞ¶ª°üµØ±¸·ÝʧЧÁ´Â·µÄÊý¾Ý´«Ê䣬ʵÏÖÁ÷Á¿µÄ¸ºÔØÆ½ºâ¼°ÈßÓ౸·Ý£»Ö§³Ö¶¯Ì¬Â·ÓÉЭÒé¡¢¿ç°å¶Ë¿Ú¾ÛºÏ¡¢ÐéÄâ·ÓÉÈßÓàЭÒ飨VRRP£©µÈ±£»¤»úÖÆ£¬ÓÐÓðü¹ÜÈ«Íø¸ßËÙ¿É¿¿ÔËÐС£

ÖÜÈ«µÄIPv6½â¾ö¼Æ»®

RG-S12000 Cloud ComputingϵÁÐÏß¿¨ÂþÑÜʽʵÏÖIPv6ÓªÒµÓ²¼þ´¦Öóͷ££¬Ö§³ÖÍòÕ×IPv6ÓªÒµÏßËÙת·¢¡£ ÖÜȫ֧³ÖIPv6ЭÒé×å¼°±àÖ·½á¹¹£¬Ö§³ÖND£¨ÁÚÈË·¢Ã÷£©¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6µÈIPv6ÌØÕ÷¡£

RG-S12000 Cloud ComputingϵÁÐÖÜȫ֧³ÖIPv6¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+µÈIPv6µ¥²¥Â·ÓÉЭÒ飬֧³ÖMLD v1/v2¡¢MLD Snooping¡¢PIM-SMv6µÈIPv6×é²¥ÌØÕ÷£¬ÎªÓû§ÌṩÍêÉÆµÄIPv4/IPv6½â¾ö¼Æ»®¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³Ö¸»ºñµÄIPv4ÏòIPv6¹ý¶ÉÊÖÒÕ£¬°üÀ¨£ºIPv6ÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢6to4ËíµÀ¡¢ISATAPËíµÀµÈËíµÀÊÖÒÕ£¬°ü¹ÜIPv4ÍøÂçÏòIPv6ÍøÂçµÄƽ»¬¹ý¶É¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³Ö¸»ºñµÄIPv6¹ÜÀíÌØÕ÷£¬Ö§³ÖSNMP v6¡¢Ping /Traceroute v6¡¢IPv6 TACACS+/ RADIUS¡¢Telnet/SSH v6¡¢NTP v6£¬Öª×ã´¿IPv6ÍøÂç×°±¸¹ÜÀíµÄÐèÒª¡£

IPFIXÁ÷Á¿Í¸Ã÷»¯¼Æ»®

RG-S12000 Cloud ComputingϵÁн»Á÷»úÔÚÒµÄÚÂÊÏÈÖ§³Ö×îÐÂÒ»´ú¹ú¼ÊÁ÷Á¿¼à¿Ø±ê×¼IPFIX£¨IP Flow Information Export£©£¬ÇкϹú¼Ê±ê×¼Éú³¤Ç÷ÊÆ£¬²¢ÏòϼæÈÝNetflow v9¡£IPFIX¶àӪҵģ¿é½ÓÄɸßÐÔÄܵÄNPƽ̨£¬Ö§³ÖÍòÕ×ÓªÒµÁ÷Á¿µÄ¼à¿Ø¡£

ÍŽá97¹ú¼ÊÁ÷Á¿ÆÊÎöϵͳ£¬IPFIXÊÖÒÕ¿ÉÒÔ¶ÔÍøÂçÖеÄËùÓÐÁ÷Á¿¾ÙÐÐͳ¼ÆÆÊÎöºÍÒì³£¼ì²â£¬Êä³öÖÖÖÖ¸»ºñµÄÍøÂçÁ÷Á¿ÆÊÎö±¨±í£¬°üÀ¨£ºÁ÷Á¿Ê¹Óñ¨±í¡¢ÀúÊ·±¨±í¡¢½Ó¿Ú±¨±í¡¢¿ÉÆÊÎöµÄÖ÷»úµØÖ·¡¢Á÷Á¿ÆÊÎö¡¢±äÁ¿ÏÔʾµÈÐÅÏ¢£¬Äܹ»×ÊÖú¹ÜÀíÔ±ÔÚÍøÂçÒì³£ÐÐΪ±¬·¢Ê±¿ìËÙÆÊÎö³öÍøÂçÖб£´æµÄÎÊÌâ£¬ÎªÍøÂçÈÝÁ¿ÍýÏë¡¢ÍøÂçÓ¦ÓÃ¼à¿ØÒÔ¼°¹ÊÕÏÕï¶ÏµÈÌṩ¿Í¹Û׼ȷµÄ¾öÒéÒÀ¾Ý£¬ÊµÏÖÕæÕýµÄÍøÂçÁ÷Á¿¿ÉÊÓ»¯¡£

IPFIX¶àӪҵģ¿é×÷Ϊ×ÔÁ¦ÓªÒµÎÞаÀ©Õ¹µ½97¹ú¼Ê½»Á÷»úÖУ¬½ÓÄÉ×ÔÁ¦µÄÓ²¼þƽ̨£¬°ü¹ÜÔÚ¶àӪҵģ¿é¾ÙÐÐά»¤»ò¹ÊÕϵÄÇéÐÎÏ£¬½¹µã×°±¸Êý¾ÝÓªÒµÕý³£×ª·¢£¬°ü¹ÜÁ˽¹µã×°±¸µÄ¸ß¿É¿¿¡£

Ó¦ÓÃÊý¾ÝÇå¾²·À»¤

97¹ú¼ÊÍøÂç·À»ðǽÄ£¿éÊÇÒµÄÚµÚÒ»¿îÕæÕýµÄ³¬ÍòÕ׸ßÐÔÄÜ·À»ðǽÄ£¿é£¬¿ÉÓ¦ÓÃÓÚRG-S12000 Cloud ComputingϵÁн»Á÷»ú¡£¼¯³ÉÁË·À»ðǽ¡¢Ó¦ÓÃÇå¾²Óò¡¢ÐéÄâ·À»ðǽºÍNATµØÖ·×ª»»µÈһϵÁй¦Ð§£¬½«ÍøÂçÓëÇå¾²×°±¸¾ÙÐÐÕæÕýµÄÈںϣ¬ÌáÉýÁ˽¹µã½»Á÷µÄÇå¾²¿ØÖÆÄÜÁ¦£¬ÎªÓû§µÄӪҵ͎áÆäÍøÂçÌṩÖÜÈ«µÄÇå¾²·À»¤¡£

97¹ú¼ÊÍøÂç·À»ðǽÄ£¿éÄÜÌṩÍⲿ¹¥»÷Ìá·À¡¢ÄÚÍøÇå¾²¡¢×´Ì¬¼ì²âµÈ¹¦Ð§ÓÐÓõİü¹ÜÍøÂçµÄÇå¾²¡£ÊµÊ±¼ì²âÖÖÖÖÍøÂçÓªÒµÅþÁ¬×´Ì¬£¬²¢ÌṩÓʼþ¸æ¾¯¡¢¹¥»÷ÈÕÖ¾¡¢Á÷ÈÕÖ¾ºÍÍøÂç¹ÜÀí¼à¿ØµÈ¹¦Ð§£¬Ð­ÖúÓû§¾ÙÐÐÍøÂç¹ÜÀí¡£Æä²úÆ·Óë»ù´¡ÍøÂç×°±¸Èںϣ¬¾ßÓм´²å¼´Óá¢À©Õ¹ÐÔÇ¿µÄÌØµã£¬½µµÍÁËÓû§¹ÜÀíÄѶÈ£¬ïÔÌ­ÁËά»¤±¾Ç®¡£

RG-S12000 Cloud ComputingϵÁн»Á÷»úÖ§³ÖCPP¡¢NFPPµÈÇå¾²·ÀÓùÊÖÒÕ£¬¿ÉʵÏÖARP¡¢DHCP¡¢ICMP¡¢IPɨÃè¡¢DHCP V6¡¢NDµÈÖÖÖÖ¹¥»÷µÄ×Ô¶¯·ÀÓù£¬¿É×Ô½ç˵¿¹¹¥»÷µÄ±¨ÎÄÀàÐÍ£¬°ü¹Ü×°±¸×Ô¼ºÒÔ¼°Õû¸öÍøÂçµÄÇå¾²¿É¿¿¡£

ÊÖÒÕ²ÎÊý

ÊÖÒÕ²ÎÊý

²ÎÊýÐÎò

²úÆ·ÐͺÅ

RG-S12010

RG-S12006

Ä£¿é²å²Û

10¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©

6¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©

±³°å´ø¿í

256T

128T

½»Á÷ÈÝÁ¿

51.8Tbps/204.8Tbps

27.6Tbps/102.4Tbps

°üת·¢ËÙÂÊ

7680Mpps/48000 Mpps

3840Mpps/24000 Mpps

802.1q VLAN

4K

ÏÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÅÌËãÍøÂçÌØÕ÷

ÔöÇ¿ÒÔÌ«ÍøÌØÕ÷£¨DCB£©

802.1Qbb: Priority-based Flow Control (PFC) £¬»ùÓÚÓÅÏȼ¶µÄÁ÷¿Ø

802.1Qaz: Enhanced Transmission Selection (ETS and DCBX)£¬ÔöÇ¿´«ÊäÑ¡Ôñ

802.1Qau: Congestion Notification (CN/QCN)£¬ÓµÈûͨ¸æ

ͳһ½»Á÷ÌØÕ÷£ºFCoE£¨Fibre Channel over Ethernet£©

ÔÆÅÌËãÓëÐéÄâ»¯ÌØÕ÷£ºTRILL¡¢VSU¡¢VEPA¡¢802.1Qbg

L2ЭÒé

IEEE802.3£¨10Base-T£©¡¢IEEE802.3u£¨100Base-T£©¡¢IEEE802.3z£¨1000Base-X£© ¡¢IEEE802.3ab£¨1000Base-T£©¡¢IEEE802.3ae£¨10GBase£©¡¢IEEE802.3ba£¨40G/100G£©¡¢IEEE802.3ak¡¢IEEE802.3an ¡¢IEEE802.3X¡¢IEEE802.3ad£¨Á´Â·¾ÛºÏ£¬Í¬Ê±Ö§³Ö¿ç°åÁ´Â·¾ÛºÏ£©¡¢IEEE802.1P¡¢IEEE802.1X¡¢IEEE802.1Q¡¢IEEE802.1D£¨STP£©¡¢IEEE802.1w£¨RSTP£©¡¢IEEE802.1s£¨MSTP£©¡¢IGMP Snooping ¡¢Jumbo Frame¡¢IEEE802.1ad£¨QinQ¡¢ÎÞаQinQ£©¡¢GVRP

L3ЭÒé(IPV4)

Ö§³ÖBGP4¡¢IS-IS¡¢OSPFv2¡¢RIPv1¡¢RIPv2¡¢MBGPµÈµ¥²¥Â·ÓÉЭÒé¡¢Route-policy¡¢ECMP¡¢WCMP¡¢VRRP¡¢Ö§³Ö×é²¥IGMP v1/v2/v3¡¢PIM-SSM/SM/DM

IPv6»ù´¡Ð­Òé

ND¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6¡¢ICMPv6¡¢ICMPv6ÖØ¶¨Ïò¡¢ACLv6¡¢TCP/UDP for IPv6¡¢SNMP v6¡¢Ping /Traceroute v6¡¢IPv6 TACACS+/ RADIUS¡¢Telnet/SSH v6¡¢FTP/TFTP v6¡¢NTP v6¡¢IPv6 MIB support for SNMP¡¢VRRP for IPv6¡¢IPv6 QoS

IPv6·ÓÉÌØÕ÷

¾²Ì¬Â·ÓÉ¡¢µÈ¼Û·ÓÉ¡¢Õ½ÂÔ·ÓÉ¡¢OSPFv3¡¢RIPng¡¢BGP4+¡¢MLDv1/v2¡¢PIM-SMv6

IPv6ËíµÀÊÖÒÕ

ÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀµÈ

MPLS VPN

¶þ¡¢Èý²ãMPLS VPN¡¢Ö§³Ö MPLS VPN¿çÓò¡¢Ö§³Ö×é²¥VPN

QoS

Ö§³ÖIP Precedence¡¢802.1P¡¢DSCP¡¢TOSµÈEXPÓÅÏȼ¶Ó³É䣬֧³ÖACLÁ÷·ÖÀ֧࣬³ÖÓÅÏȼ¶±ê¼ÇMark/Remark£¬Ö§³ÖSP¡¢RR¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRR¡¢WFQµÈ¶àÖÖÐÐÁе÷Àí»úÖÆ£¬Ö§³ÖWRED¡¢REDÓµÈû×èÖ¹£¬Ö§³ÖCAR¡¢LR£¨In/Out£©Á÷Á¿ÕûÐι¦Ð§¡¢HOL£¬Ö§³ÖVoQ

¸ß¿É¿¿Éè¼Æ

Ö§³ÖVSU¡¢Ö§³ÖGR for ISIS/BGP/OSPFµÈ·ÓÉЭÒé¡¢Ö§³ÖISSU¡¢Ö§³ÖRERP¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖTPP

Ö§³ÖË«ÒýÇæÈȱ¸¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢½ÓÄÉÎÞÔ´±³°åÉè¼Æ¡¢µçÉȽÓÄÉÈßÓàÉè¼Æ¡¢ËùÓÐÏß¿¨Ä£¿éºÍµçÔ´Ä£¿éÖ§³ÖÈȲå°Î¹¦Ð§¡¢Ö§³Ö½»Á÷¾ØÕóÈßÓ౸·Ý¸ß¿É¿¿Éè¼Æ

רҵÇå¾²ÊÖÒÕ

NFPP¡¢CPP¡¢·ÀDDOS¹¥»÷¡¢²»·¨Êý¾Ý°ü¼ì²â¡¢Êý¾Ý¼ÓÃÜ¡¢·ÀÔ´IPÓÕÆ­¡¢·ÀIPɨÃ裬֧³Ö±ê×¼ºÍÀ©Õ¹ACL ¡¢Ö§³ÖIngress/Egress ACL¡¢Ö§³ÖVLAN ACL¡¢Ö§³ÖÈ«¾Ö ACL£¬Ö§³ÖOSPF¡¢RIPv2 ¼°BGPv4 ±¨ÎĵÄÃ÷Îļ°MD5ÃÜÎÄÈÏÖ¤¡¢Ö§³ÖÊÜÏÞµÄIPµØÖ·µÄTelnetµÄµÇ¼ºÍ¿ÚÁî»úÖÆ¡¢uRPF¡¢Ö§³Ö¹ã²¥±¨ÎÄÒÖÖÆ¡¢DHCP Snooping£¬Ö§³ÖRADIUS/TACACS+

¹ÜÀí·½·¨

Ö§³ÖSyslogϵͳÊÂÇéÈÕÖ¾£¬Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´¡¢Ö§³ÖUSB¡¢Ö§³ÖSNTP¡¢NTPʱÖÓ¡¢Ö§³ÖRMON£¬Ö§³Ö1¡¢2¡¢3¡¢9×飬֧³ÖSNMP v1/v2/v3c£¬Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ÏÂÁîÐÐÉèÖã¬Ö§³ÖFTP¡¢TFTP¡¢Xmodem¡¢Ö§³ÖSPAN/RSPAN/ERSPAN£¬Ö§³ÖIPFIXÁ÷Á¿ÆÊÎö

PoE¹©µç

Ö§³ÖPoE¹©µç¹¦Ð§£¬¿ÉÉèÖÃPoEÏß¿¨£¬ÊµÏÖÎÞÏß½ÓÈë¡¢ÊÓÆµ¼à¿Ø¡¢×Ô¶¯¿ØÖÆÏµÍ³¡¢ÎÞÏßÉäÆµÊ¶±ðϵͳRFIDµÈ¶àÓªÒµÓ¦ÓÃÖն˵ÄÒÔÌ«Íø¹©µç

ÆäËüЭÒé

DHCP Client¡¢DHCP Relay¡¢DHCP Server¡¢DNS Client¡¢UDP relay¡¢ARP Proxy¡¢Domain¡¢VPN¡¢Syslog¡¢IPFIX

³ß´ç£¨¿íxÉîx¸ß£©(mm)

437 x 450 x 930.65£¬¸ß¶È21U

437 x 500 x 486.15£¬¸ß¶È11U

µçÔ´

RG-PA1200I£º90V~176V£¬¹¦ÂÊ£º530W£»176V~264V£¬¹¦ÂÊ£º1400W

RG-PA2000I£º90V~176V£¬¹¦ÂÊ£º1080W£»176V~264V£¬¹¦ÂÊ£º2000W

MTBF

> 200,000 Сʱ

ζÈ

ÊÂÇéζȣº0¡æ  µ½ 50¡æ

´æ´¢Î¶ȣº-40¡æ µ½ 70¡æ

ʪ¶È

ÊÂÇéʪ¶È£º10% µ½ 90% RH

´æ´¢Êª¶È£º10% µ½ 90% RH

 

Õö¿ªÏêϸ²ÎÊý

Ó¦Óó¡¾°

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌ⣬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼