8¿ÚǧÕ×µç½ÓÈë½»Á÷»ú£¬4¸ö1000BASE-X SFP¹â¿Ú£¬RG-IS2712G

ÄÜÖª×ãÆ½°²¶¼»á¡¢ÖÇÄܽ»Í¨¡¢ÊÒÍâ¼à¿ØºÍÆäËû±°ÁÓÇéÐÎÖеݲÅÅÒªÇó

²úÆ·ÌØÕ÷£º

  • ¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢Îȹ̵Ä×°±¸ÐÔÄÜ
  • ÐéÄ⻯ÊÖÒÕ
  • ¸»ºñµÄÍøÂ繦ЧÓëÇå¾²ÌØÕ÷
  • ÎÞаµÄ×éÍø£¬Ç³Ò׵ĹÜÀí
Á¬Ã¦×Éѯ

¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢Îȹ̵Ä×°±¸ÐÔÄÜ

¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡£×ñÕÕ¹¤Òµ¼¶Éè¼Æ¹æ·¶£¬½ÓÄɹú¼Ê´ó³§Ö÷Á÷³ÉÊ칤ҵ¼¶Ð¾Æ¬¡¢¸ßÐÔÄܹ¤Òµ¼¶ CPU¡¢¹¤Òµ¼¶µçÔ´Ä £¿éºÍÂÁºÏ½ðÍâ¿Ç£¬°ü¹Ü²úÆ·µÄ¹¤Òµ¼¶Æ·ÖÊ¡£

½ÓÄÉÎÞµçÉÈÉ¢Èȵç·Éè¼Æ¡¢Ö§³Ö-40~85ºCÊÂÇéÇéÐÎζȡ¢IP40 ·À»¤Æ·¼¶¡¢·ÀÀ×µçѹ>=8KV¡¢·ÀÕñ¶¯±£»¤µçÔ´Éè¼Æ¡¢µç´Å×ÌÈÅËļ¶±ê×¼¡¢Ä͹¥»÷ºÍÕñ¶¯£¬×°±¸¼´±ãÔÚ±°ÁÓÇéÐÎÖÐÒ²ÄÜÎȹ̿ɿ¿µÄÔËÐС£

ÐéÄ⻯ÊÖÒÕ

Ö§³ÖVSU£¨Virtual Switch Unit£©¼´ÐéÄâ½»Á÷µ¥Î»ÊÖÒÕ¡£Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬×î¶à¿É½«8̨ÎïÀí×°±¸ÐéÄâΪһ̨Âß¼­ÉÏͳһµÄ×°±¸£¬Ê¹ÆäÄܹ»ÊµÏÖͳһµÄÔËÐУ¬Ê¹Óüòµ¥IPµØÖ·¡¢¼òµ¥TelnetÀú³Ì¡¢¼òµ¥ÏÂÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÉèÖõÈÌØÕ÷¼ò»¯Á˹ÜÀí¡£

¸»ºñµÄÍøÂ繦ЧÓëÇå¾²ÌØÕ÷

Ö§³ÖVLAN¡¢STP/RSTP ¡¢ERPS¡¢×é²¥¡¢¶Ë¿Ú¾µÏñ¡¢QoS¡¢¶Ë¿ÚÇå¾²¡¢¹ã²¥·ç±©ÒÖÖÆµÈ¶þ²ãÌØÕ÷£»Ö§³Ö¾²Ì¬Â·ÓɵÈÈý²ãÍøÂçЭÒé¡£

ͨ¹ý¶àÖÖÄÚÔÚµÄÇå¾²»úÖÆ¿ÉÓÐÓñÜÃâºÍ¿ØÖƲ¡¶¾Èö²¥ºÍÍøÂçÁ÷Á¿¹¥»÷£¬¿ØÖƲ»·¨Óû§Ê¹ÓÃÍøÂ磬°ü¹ÜÕýµ±Óû§ºÏÀí»¯Ê¹ÓÃÍøÂ磬Èç¶Ë¿Ú¾²Ì¬ºÍ¶¯Ì¬µÄÇå¾²°ó¶¨¡¢¶Ë¿Ú¸ôÀë¡¢¶àÖÖÀàÐ͵ÄÓ²¼þACL¿ØÖÆ¡¢»ùÓÚÊý¾ÝÁ÷µÄ´øÍÑÆÚËÙ¡¢Óû§½ÓÈë¿ØÖÆµÄ¶àÔªËØ°ó¶¨µÈ£¬Öª×ãÄúÍøÂç¶Ô×°±¸½ÓÈëµÄÇå¾²¿ØÖÆ¡£

»ù´¡ÍøÂç±£»¤£¨NFPP£©Í¨¹ý½«±¨ÎÄ·ÖÀàÏÞËÙ£¨¹ÜÀíÀࡢת·¢ÀࡢЭÒéÀࣩ£¬²¢¶Ô±¨ÎľÙÐй¥»÷¼à²â£¬Ë«Öذü¹Ü±£»¤CPUºÍÐŵÀ´ø¿í×ÊÔ´ÃâÊܹ¥»÷·³ÈÅ£¬°ü¹Ü±¨ÎĵÄÕý³£×ª·¢ÒÔ¼°Ð­Òé״̬µÄÕý³££¬Î¬»¤ÍøÂçµÄÎȹÌ¡£

ÎÞаµÄ×éÍø£¬Ç³Ò׵ĹÜÀí

Ö§³Ö¹Å°åµÄÐÇÐÎ×éÍøÄ£Ê½¡¢Í¬Ê±Ò²Ö§³ÖÒÔÌ«Íø¶à»·±£»¤ÊÖÒÕ£¨ERPS£©ÊµÏÖ»·Ðη½·¨×éÍø£¬¸Ã×éÍø·½·¨¾ßÓкܸߵÄÈßÓà¿É¿¿ÐÔ£¬Ò»µ©»·Â·ÓÐÒ»½Úµã·ºÆð¹ÊÕÏ£¬¿ÉÒÔ´ÓÁíÒ»¶Ë¾ÙÐÐÊý¾Ýת·¢£¬Çл»Ê±¼ä≤20ms¡£Óë´Ëͬʱ£¬»·Íø·½·¨Ïà±ÈÐÇÐÎ×éÍø¸ü½ÚÔ¼¹âÏË£¬¿ÉÒÔΪÄú½ÚÔ¼Ò»¶¨µÄ½¨É豾Ǯ¡£

½ÓÄÉÎÞаµÄǧÕ×µç¿Ú+¹â¿Ú£¨·Ç¸´Ó㩵ÄÐÎʽ£¬Àû±ãÓû§Æ¾Ö¤ÍøÂç¼Ü¹¹ÎÞаѡÔñÅþÁ¬ÐÎʽ¡£

ͬʱ֧³ÖʹÓùŰåCLIÏÂÁîÐз½·¨ºÍWebͼÐλ¯½çÃæ·½·¨ÉèÖý»Á÷»ú£¬ÎÞÐèÏàÊ¶ÖØ´óµÄÏÂÁîÐкÍÖÕ¶ËÄ£Äâ³ÌÐò£¬ÔÊÐí¼òÆÓ¡¢¿ìËÙµÄÉèÖý»Á÷»ú£¬´Ó¶ø½µµÍ°²ÅÅÄѶÈ¡£

SyslogÀû±ãÖÖÖÖÈÕÖ¾ÐÅÏ¢µÄÍ³Ò»ÍøÂ硢ά»¤¡¢ÆÊÎö¡¢¹ÊÕ϶¨Î»¡¢±¸·Ý£¬±ãÓÚ¹ÜÀíÔ±¾ÙÐÐÍøÂçά»¤ºÍ¹ÜÀí¡£

ÊÖÒÕ²ÎÊý

²úÆ·ÐͺÅ

RG-IS2712G

RG-IS2712G-DC

RG-IS2706G

¹Ì»¯¶Ë¿Ú

8¸ö10/100/1000M µç¿Ú£»4¸ö1000BASE-X SFP¹â¿Ú

4¸ö10/100/1000M µç¿Ú£»2¸ö1000BASE-X SFP¹â¿Ú

À©Õ¹Ä £¿é

ÎÞ

¹ÜÀí¿Ú

1¸öConsole ¶Ë¿Ú

Ò»¼üÖØÆô

Ö§³ÖÒ»¼üÖØÆô

½»Á÷ÈÝÁ¿

128G

°üת·¢ËÙÂÊ

26.7Mpps

13.4Mpps

802.1q VLAN

4K

ÊÂÇéÇéÐÎ

ÊÂÇéζÈ-40¡«85¡æ

ÊÂÇéʪ¶È5¡«95%RH

·À»¤Æ·¼¶IP40

¶Ë¿Ú·ÀÀ×≥8KV

ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£©£º30ÄêÒÔÉÏ

µç´Å×ÌÈÅ

ESD (IEC 61000-4-2)                  Level 4 (8K/15K)

RS (IEC 61000-4-3)                    Level 3 (10V/m)

EFT (IEC 61000-4-4)                  Level 3 (1V/2V)

CS (IEC 61000-4-6)                    Level 3 (10V/m)

PFMF (IEC 61000-4-8)                Level4£¨30A/m£©

Surge (IEC 61000-4-5)                Level 4+(6KV/2KV)

DIP (IEC 61000-4-11)                 Level3 (10V)

L2ЭÒé

G.8032 (ERPS)¡¢IEEE802.3¡¢IEEE802.3u¡¢IEEE802.3z ¡¢IEEE802.3x¡¢IEEE802.3ad¡¢IEEE802.1p¡¢

IEEE802.1x¡¢IEEE802.3ab¡¢IEEE802.1Q¡¢IEEE802.1d¡¢IEEE802.1w¡¢IEEE802.1s¡¢

IGMP Snooping v1/v2/v3

ACL

±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©

À©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

MACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©»ùÓÚʱ¼äACL

ר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£©

IPv6 ACL&QoS

Ö§³Ö»ùÓÚÔ´/Ä¿µÄIPv6µØÖ·¡¢Ô´/Ä¿µÄ¶Ë¿ÚµÄIPv6 ACLºÍIPv6 QoS

ÓÅÏȼ¶ÐÐÁÐ:8

Çå¾²ÌØÕ÷

Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

¹ýÂ˲»·¨µÄMACµØÖ·

Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x

Ö§³ÖWEBÈÏÖ¤£¬ºÍ802.1X¡¢ARP-Check¡¢ACL¿Éͬʱ¿ªÆô

Ö§³ÖARP-Check

Ö§³ÖDAI

Ö§³ÖARP±¨ÎÄÏÞËÙ

Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ

¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤

×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£©

Ö§³ÖSSH

Ö§³ÖBPDU Guard

Ö§³ÖDOS¹¥»÷·À»¤¡¢ARP¹¥»÷·À»¤¡¢ICMP¹¥»÷·À»¤

Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿ÚÇå¾²

Ö§³Ö±¨¾¯¶Ë¿Ú¹¦Ð§

IP·ÓÉ

Ö§³Öȱʡ·ÓÉ£¬Ö§³ÖÖ÷»ú¼°Ö±Á¬Íø¶ÎµÄ¾²Ì¬Â·ÓÉ

IPv6ЭÒé

IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ

¹ÜÀíÌØÕ÷

SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢Web

»úе½á¹¹

³ß´ç£º52*115*160mm (W×H×D)

×°Ö÷½·¨: DIN¿¨¹ìʽ»ò±Ú¹Òʽ

µçÔ´

½»Á÷£¨AC£©ÊäÈ룺

¶î¶¨µçѹ¹æÄ££º100-240V~

×î´óµçѹ¹æÄ££º90-264V~

ƵÂÊ£º50-60Hz

¶î¶¨µçÁ÷£º0.4A

 

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺

¶î¶¨µçѹ¹æÄ££º140-340VDC

×î´óµçѹ¹æÄ££º130-370VDC

¶î¶¨µçÁ÷£º0.4A

 

Ö±Á÷£¨DC£©ÊäÈ룺

24DCW£¨18-72VDC£©&48DCW£¨18-72VDC£©

Ë«ÈßÓàÊäÈë

¹¦ºÄ

Õû»ú¹¦ºÄ≤11.5W

Õû»ú¹¦ºÄ≤8W

É¢ÈÈ

ÎÞµçÉÈÉè¼Æ£¬¸ßЧɢÈÈÆ¬É¢ÈÈ

 

Õö¿ªÏêϸ²ÎÊý

Ó¦Óó¡¾°

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
¿íÎÂ(1)
97¹ú¼Ê 2022Äê07ÔÂ25ÈÕ
RG-IS2700GϵÁй¤ÒµÒÔÌ«Íø½»Á÷»úÊÇ·ñÊÇ¿íν»Á÷»ú £¿
ÓÐÓÃ 29 ÎÞÓÃ 1

ÊǵÄ£¬¸Ã¿î½»Á÷»úΪÎÒ˾¹¤Òµ½»Á÷»ú¡£¹¤Òµ½»Á÷»ú¶¼ÊÇ¿íÎÂÉè¼ÆµÄ¡£

c**** 2023Äê08ÔÂ15ÈÕ
¹¤Òµ½»Á÷»úÓëÆäËûµÄ½»Á÷»úÓÐʲô²î±ðÂ𠣿
ÓÐÓÃ 23 ÎÞÓÃ 1
¹¤Òµ½»Á÷»úÊÇרÓÃÓÚ¹¤Òµ¿ØÖÆÁìÓòµÄ¹¤Òµ¼¶½»Á÷»ú£¬¹¤ÒµÒÔÌ«Íø½»Á÷»úÒ²ÊÇÖ¸Ëü£¬Òò´ËÓÉÓÚÓ¦Óó¡ºÏ²î±ð£¬¹¤Òµ½»Á÷»úÓëÆäËûͨË׵Ľ»Á÷»úÔÚÍâ¹ÛºÍ×°ÖÃÐÎʽÉÏÓÐÇø±ð£¬Í¬Ê±ÐÔÄܺ͹¦Ð§Ò²ÓÐËù²î±ð£¬¹¤Òµ½»Á÷»ú¶Ô·ÀË®¡¢·À³¾¡¢¿¹×ÌÈŵÄÒªÇó½Ï¸ß£¬ÒªÓÐÄܹ»³¤Ê±¼äÔËÐеÄÄÜÁ¦£¬Í¬Ê±²»ÖÐÖ¹¡¢ÑÓʱµÍ£¬¶øÒ»Ñùƽ³£µÄ½»Á÷»úûÓÐÕâô¸ßµÄÒªÇó¡£
Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ £¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖà £¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù £¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£© £¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£© £¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼