Àο¿¶Ë¿Ú
|
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö1G SFP¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö10G/1G SFP+¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
|
48¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö1G SFP¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
48¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö10G/1G SFP+¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
|
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö1G SFP¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬4¸ö10G/1G SFP+¹â¿Ú£¬¹Ì»¯µ¥½»Á÷µçÔ´
24¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W
|
48¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬2¸ö100/1000M¸´ÓÃSFP¿Ú£¬2¸ö10G/1G SFP+¹â¿Ú, Ë«À©Õ¹²Û£¬³ö³§×Ô´øÒ»¸ö½»Á÷µçÔ´
48¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W
|
½»Á÷ÈÝÁ¿
|
336Gbps/3.36Tbps
|
432Gbps/4.32Tbps
|
336Gbps/3.36Tbps
|
432Gbps/4.32Tbps
|
°üת·¢ÂÊ
|
51Mpps/126Mpps
108Mpps/126Mpps
|
87Mpps/166Mpps
144Mpps/166Mpps
|
51Mpps/126Mpps
108Mpps/126Mpps
|
144Mpps/166Mpps
|
PoE
|
²»Ö§³Ö
|
²»Ö§³Ö
|
¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷDZê×¼PD×°±¸
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
|
MACµØÖ·±í
|
Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
|
802.1Q VLAN
|
Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
|
QinQ
|
Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
|
¶þ²ã»·ÍøÊÖÒÕ
|
Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐÒéERPS£¬Çл»Ê±¼ä≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃÐÒéµÄ²úÆ·¼æÈÝ
|
¶Ë¿Ú¾ÛºÏ
|
Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ÐÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖÃ
Ö§³Ö¿çVSU AP
|
Mirror
|
Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢RSPAN
Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ
|
DHCP
|
Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
|
VSUÌØÕ÷
|
Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Öͨ¹ý±ê×¼ÓªÒµ¿ÚʵÏÖÐéÄ⻯
|
IP·ÓÉ
|
¾²Ì¬Â·ÓÉ¡¢¿ÉÀ©Õ¹Ö§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ÐÒé
|
ACL
|
Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
|
QoS
|
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
|
Çå¾²ÌØÕ÷
|
¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
|
EEE
|
Ö§³ÖIEEE 802.3az ±ê×¼µÄ EEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ¡£
|
¹ÜÀíÌØÕ÷
|
SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢MACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨¹ÜÀí
|
µçÔ´
|
½»Á÷£¨AC£©ÊäÈ룺 ¶î¶¨µçѹ¹æÄ££º100V~240V
×î´óµçѹ¹æÄ££º90V~264V
ƵÂÊ£º50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹ¹æÄ£: 192~290V
|
µçÉÈ
|
²¿·ÖÐͺÅÖ§³ÖÎÞµçÉÈ£¬×ÔȻɢÈÈ
ÓеçÉÈÐͺÅÖ§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§
|
¹¦ºÄ
|
≤24W
|
≤40W
≤50W
|
Õû»ú¹¦ºÄ£¨²»´øPOE¸ºÔØ£©<40W
Õû»ú¹¦ºÄ£¨PoEÂúÔØ£©<460W
|
ĬÈÏÕû»ú¹¦ºÄ£¨PoEÂúÔØ£©<460W
|
ζÈ
|
ÊÂÇéζȣº0¡æ~50¡æ
´æ´¢Î¶ȣº-40¡æ~70¡æ
|
ʪ¶È
|
ÊÂÇéʪ¶È£º10%~90%RH
´æ´¢Êª¶È£º5%~95%RH
|